Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 15 von 151

Details

Autor(en) / Beteiligte
Titel
Determining real-time mass deposition with a quartz crystal microbalance in an electrostatic, parallel-flow, air-liquid interface exposure system
Ist Teil von
  • Journal of aerosol science, 2021-01, Vol.151, p.105653, Article 105653
Ort / Verlag
England: Elsevier Ltd
Erscheinungsjahr
2021
Link zum Volltext
Quelle
Elsevier ScienceDirect Journals Complete
Beschreibungen/Notizen
  • In vitro studies are the first step toward understanding the biological effects of particulate matter. As a more realistic exposure strategy than submerged culture approaches, air-liquid interface (ALI) in vitro exposure systems are gaining interest. One challenge with ALI systems is determining accurate particle mass deposition. Although a few commercially available ALI systems are equipped with online mass deposition monitoring, most studies use indirect methods to estimate mass doses. These different indirect methods may contribute to inconsistencies in the results from in vitro studies of aerosolized nanoparticles. This study explored the effectiveness of using a commercially available Quartz Crystal Microbalance (QCM) to estimate the real-time, particle-mass deposition inside an electrostatic, parallel-flow, ALI system. The QCM system required minor modifications, including custom-designed and fabricated headers. Three QCM systems were simultaneously placed in three of the six wells in the ALI exposure chamber to evaluate the uniformity of particle deposition. The measurements from fluorescein dosimetry and QCM revealed an uneven deposition between these six wells. The performance of the QCM system was also evaluated using two different methods. First, using fluorescein deposition in one well, depositions in three other wells were estimated, which was then compared to the actual QCM readings. Second, using the QCM measured deposition in one well, the deposition in three other wells was estimated and compared to deposition measured by fluorescein dosimetry. For both methods, the expected and actual deposition yields a linear fit with the slope ~1. This good fit suggests that QCM systems can be used to measure real-time mass deposition in an electrostatic ALI system. •Commercial QCM systems can effectively measure mass deposition in an ALI system.•Deposition in the six exposure wells of ALI is not uniform.•Relative deposition parameters can address the well-to-well deposition differences.•Deposition as low as 50 ng/cm2 can be measured by QCM in electrostatic ALI system.
Sprache
Englisch
Identifikatoren
ISSN: 0021-8502
eISSN: 1879-1964
DOI: 10.1016/j.jaerosci.2020.105653
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7529104

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX