Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 12 von 372152

Details

Autor(en) / Beteiligte
Titel
Lack of agreement between different observers and methods in the measurement of capillary refill time in healthy volunteers: an observational study
Ist Teil von
  • Revista Brasileira de terapia intensiva, 2014-07, Vol.26 (3), p.269-276
Ort / Verlag
Brazil: Associação Brasileira de Medicina intensiva
Erscheinungsjahr
2014
Quelle
MEDLINE
Beschreibungen/Notizen
  • Peripheral perfusion abnormalities are relevant manifestations of shock. Capillary refill time is commonly used for their evaluation. However, the reproducibility of capillary refill time measurements and their correlation with other variables of peripheral perfusion, have not been comprehensively evaluated. Our goal was to determine, in healthy volunteers, the agreement between different methods of capillary refill time quantification and different observers, as well as their correlation with other markers of peripheral perfusion. Methods: We studied 63 healthy volunteers. Two observers measured capillary refill time by means of two methods, direct view (CRTchronome ter) and video analysis (CRTvideo). We also measured perfusion index (PI) derived from pulse plethysmography and finger pad temperature (T°peripheral). The agreement between observers and methods was assessed using the Bland and Altman method. Correlations were calculated using Pearson's correlation. A p-value<0.05 was considered significant. The 95% limits of agreement between the two observers were 1.9 sec for CRTchronometer and 1.7 sec for CRTvideo. The 95% limits of agreement between CRTchronometer and CRTvideo were 1.7 sec for observer 1 and 2.3 sec for observer 2. Measurements of CRTchronometer performed by the two observers were correlated with T°peripheral. Measurements of CRTvideo performed by the two observers were correlated with T°peripheral and perfusion index. In healthy volunteers, measurements of capillary refill time performed by either different observers or different methods showed poor agreement. Nevertheless, capillary refill time still reflected peripheral perfusion as shown by its correlation with objective variables of peripheral perfusion.
Sprache
Englisch
Identifikatoren
ISSN: 0103-507X
eISSN: 1982-4335
DOI: 10.5935/0103-507X.20140038
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4188463

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX