Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Translation of a manual process to high throughput for research and development requires special consideration. One important and often unreported aspect is the establishment of an efficient cleaning routine. This becomes significant, as precious time and, in particular, material would be lost, that is, when low-quality high-throughput experimentation is involved. We present a fully automated cleaning routine of the challenging synthesis of cadmium selenide quantum dots. Manual, semiautomated, and fully automated cleaning protocols were executed and compared in terms of spectral similarities of the synthesized colloids. Only the fully automated protocol enabled true 24/7 operation.
Sprache
Englisch
Identifikatoren
ISSN: 2156-8952
eISSN: 2156-8944
DOI: 10.1021/acscombsci.9b00122
Titel-ID: cdi_proquest_miscellaneous_2299768736
Format
–
Weiterführende Literatur
Empfehlungen zum selben Thema automatisch vorgeschlagen von bX