Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 8 von 8

Details

Autor(en) / Beteiligte
Titel
Impact of Changes in Left Ventricular Ejection Fraction on Survival After Transapical Aortic Valve Implantation
Ist Teil von
  • The Annals of thoracic surgery, 2017-02, Vol.103 (2), p.559-566
Ort / Verlag
Netherlands: Elsevier Inc
Erscheinungsjahr
2017
Link zum Volltext
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • Background This single-center retrospective study assessed the variation of left ventricular ejection fraction (LVEF) after transapical transcatheter aortic valve implantation and its effect on survival. We also evaluated the effect of sheath diameter on LVEF. Methods We analyzed data of all consecutive patients who underwent transapical transcatheter aortic valve implantation with the Sapien (Edwards Lifesciences, Irvine, CA) device (and its evolutions) between 2009 and 2015. We analyzed the difference between preoperative LVEF and LVEF at discharge (ΔEF = LVEFpost-op – LVEFpre-op) and considered its interquartile range (±5%) as the cutoff. Patients were divided in three groups: (1) improved LVEF (ΔEF ≥ +5%); (2) unchanged LVEF (ΔEF –5% to +5%), and (3) worsened LVEF (ΔEF ≤ –5%). Survival was evaluated with Kaplan-Meier analysis, and logistic regression multivariable analysis was used to determine independent predictors of LVEF improvement. Results Data of 122 patients were analyzed. Patients in the three groups were distributed as follows: (group 1) 27 patients (22.1%), (group 2) 69 (56.6%), and (group 3) 26 (21.3%). The mean ΔEF was 12.7% ± 4.7% in group 1 and –10.8% ± 3.9% in group 3. The ΔEF was more likely to improve in patients with preoperative LVEF of less than 0.35 ( p  = 0.014). There were no significant differences in survival ( p  = 0.41), rehospitalization ( p  = 0.472), and New York Heart Association Functional Classification ( p  = 0.307) among the groups. The use of the smallest available sheath (18F) was not associated with a significant change of ΔEF. Conclusions LVEF worsened in a small number of patients after transapical transcatheter aortic valve implantation, but this change was not associated with worse postoperative outcomes. Patients with a low LVEF showed better improvement. The progressive reduction of sheath diameter does not have a significant effect on LVEF changes.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX