Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Measurements of proportional scintillation and electron multiplication in liquid xenon using thin wires
Ist Teil von
Journal of instrumentation, 2014-11, Vol.9 (11), p.P11012-P11012
Erscheinungsjahr
2014
Link zum Volltext
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
Proportional scintillation in liquid xenon has a promising application in the field of direct dark matter detection, potentially allowing for simpler, more sensitive detectors. However, knowledge of the basic properties of the phenomenon as well as guidelines for its practical use are currently limited. We report here on measurements of proportional scintillation light emitted in liquid xenon around thin wires. The maximum proportional scintillation gain of 287 sub(-75) super(+97) photons per drift electron was obtained using 10 [mu]m diameter gold plated tungsten wire. The thresholds for electron multiplication and proportional scintillation are measured as 725 sub(-139) super(+48) and 412 sub(-133) super(+10) kV/cm, respectively. The threshold for proportional scintillation is in good agreement with a previously published result, while the electron multiplication threshold represents a novel measurement. A complete set of parameters for the practical use of the electron multiplication and proportional scintillation processes in liquid xenon was also obtained for the first time.