Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 25 von 46

Details

Autor(en) / Beteiligte
Titel
Accuracy of a Single, Heparin-Calibrated Anti-Xa Assay for the Measurement of Rivaroxaban, Apixaban, and Edoxaban Drug Concentrations: A Prospective Cross-Sectional Study
Ist Teil von
  • Frontiers in cardiovascular medicine, 2022-03, Vol.9, p.817826-817826
Ort / Verlag
Switzerland: Frontiers Media S.A
Erscheinungsjahr
2022
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • Applying a single anti-Xa assay, calibrated to unfractionated heparin to measure rivaroxaban, apixaban, and edoxaban would simplify laboratory procedures and save healthcare costs. We hypothesized that a heparin-calibrated anti-Xa assay would accurately measure rivaroxaban, apixaban, and edoxaban drug concentrations and correctly predict clinically relevant drug levels. This analysis is part of the Simple-Xa study, a prospective multicenter cross-sectional study conducted in clinical practice. Patients treated with rivaroxaban, apixaban, or edoxaban were included. Anti-Xa activity was measured using the Siemens INNOVANCE Heparin assay. Drug concentrations were determined using ultra-high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). Cut-off levels were determined in a derivation dataset (50% of patients) and sensitivities and specificities were calculated in a verification dataset (50% of patients). Overall, 845 patients were available for analysis. Correlation coefficients (r ) between the heparin-calibrated anti-Xa assay and drug concentrations were 0.97 (95% CI 0.97, 0.98) for rivaroxaban, 0.96 (0.96, 0.97) for apixaban, and 0.96 (0.94, 0.99) for edoxaban. The area under the receiver operating characteristics curve (ROC) was 0.99 for all clinically relevant drug concentrations. In the verification dataset, the sensitivity was 94.2% (95% CI 90.8-96.6) for 30 μg L , 95.8% (92.4-98.0) for 50 μg L , and 98.7% (95.5-99.9) for 100 μg L . Specificities were 86.3% (79.2-91.7), 89.8% (84.5-93.7), and 88.7% (84.2-92.2), respectively. In a large prospective study in clinical practice, a strong correlation of heparin-calibrated anti-Xa measurements with LC-MS/MS results was observed and clinically relevant drug concentrations were predicted correctly.
Sprache
Englisch
Identifikatoren
ISSN: 2297-055X
eISSN: 2297-055X
DOI: 10.3389/fcvm.2022.817826
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_e9cb8337cd7d400ba593bd486e7b2537

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX