Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 14 von 29

Details

Autor(en) / Beteiligte
Titel
Standard Flow Multiplexed Proteomics (SFloMPro)-An Accessible Alternative to NanoFlow Based Shotgun Proteomics
Ist Teil von
  • Proteomes, 2022-01, Vol.10 (1), p.3
Ort / Verlag
Switzerland: MDPI AG
Erscheinungsjahr
2022
Link zum Volltext
Quelle
EZB Free E-Journals
Beschreibungen/Notizen
  • Multiplexed proteomics using isobaric tagging allows for simultaneously comparing the proteomes of multiple samples. In this technique, digested peptides from each sample are labeled with a chemical tag prior to pooling sample for LC-MS/MS with nanoflow chromatography (NanoLC). The isobaric nature of the tag prevents deconvolution of samples until fragmentation liberates the isotopically labeled reporter ions. To ensure efficient peptide labeling, large concentrations of labeling reagents are included in the reagent kits to allow scientists to use high ratios of chemical label per peptide. The increasing speed and sensitivity of mass spectrometers has reduced the peptide concentration required for analysis, leading to most of the label or labeled sample to be discarded. In conjunction, improvements in the speed of sample loading, reliable pump pressure, and stable gradient construction of analytical flow HPLCs has continued to improve the sample delivery process to the mass spectrometer. In this study we describe a method for performing multiplexed proteomics without the use of NanoLC by using offline fractionation of labeled peptides followed by rapid "standard flow" HPLC gradient LC-MS/MS. Standard Flow Multiplexed Proteomics (SFloMPro) enables high coverage quantitative proteomics of up to 16 mammalian samples in about 24 h. In this study, we compare NanoLC and SFloMPro analysis of fractionated samples. Our results demonstrate that comparable data is obtained by injecting 20 µg of labeled peptides per fraction with SFloMPro, compared to 1 µg per fraction with NanoLC. We conclude that, for experiments where protein concentration is not strictly limited, SFloMPro is a competitive approach to traditional NanoLC workflows with improved up-time, reliability and at a lower relative cost per sample.
Sprache
Englisch
Identifikatoren
ISSN: 2227-7382
eISSN: 2227-7382
DOI: 10.3390/proteomes10010003
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_6b2bad6d96e346468066c60a83c468c3

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX