Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 16 von 5062
Geophysical journal international, 2024-01, Vol.236 (3), p.1234-1245
2024

Details

Autor(en) / Beteiligte
Titel
The effect of heterogeneous contact impedances on complex resistivity measurements
Ist Teil von
  • Geophysical journal international, 2024-01, Vol.236 (3), p.1234-1245
Ort / Verlag
Oxford University Press
Erscheinungsjahr
2024
Link zum Volltext
Beschreibungen/Notizen
  • SUMMARY Spectral induced polarization (SIP) and electrical impedance tomography (EIT) are advanced approaches for structural characterisation of soils and rocks based on measurements of the frequency-dependent complex electrical resistivity. Accurate SIP and EIT measurements require the reduction of electrode effects, which have often been attributed to the polarization of metal electrodes in the current pathway. In this study, we demonstrate an alternative electrode effect that influences the accuracy of complex impedance measurements. This alternative electrode effect is caused by a heterogeneous distribution of the contact impedance, which can occur due to ageing or corrosion of the electrode. First, theoretical considerations are given to explain how this electrode effect influences the accuracy of complex impedance measurements. Next, we demonstrate using SIP and EIT measurements that this alternative mechanism better explains the observed electrode effects than previous explanations based only on the presence of metal. The SIP measurements were made on a water-filled container with a metal sphere between two non-polarizing electrodes, which showed that the mere presence of metal in the current pathway only leads to small electrode effects that are typically well below 1 mrad even for small electrode spacings. When the same metal sphere was used as a potential electrode, the observed electrode effect was about 2.5 times larger and varied with rotation. These changes can be explained by a heterogeneous contact impedance resulting in a varying electrode voltage. The EIT measurements were performed with a cylindrical sample holder filled with water. They are used to illustrate how the presented theoretical considerations can be used to investigate the magnitude of the electrode effects for different electrode configurations. We conclude that electrode effects are important to consider for laboratory SIP and EIT measurements and field measurement with closely spaced electrodes.
Sprache
Englisch
Identifikatoren
ISSN: 0956-540X
eISSN: 1365-246X
DOI: 10.1093/gji/ggad477
Titel-ID: cdi_crossref_primary_10_1093_gji_ggad477
Format

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX