Requirements and Pitfalls of Dialyzer Sieving Coefficients Comparisons
Ist Teil von
  • Artificial organs, 2018-12, Vol.42 (12), p.1164-1173
Ort / Verlag
United States: Wiley Subscription Services, Inc
Erscheinungsjahr
2018
Link zum Volltext
Quelle
Wiley Online Library
Beschreibungen/Notizen
  • Sieving coefficients reported in dialyzer data sheets and instructions for use (IFUs) indicate the potential of different solutes to pass across a particular membrane. Despite being measured in vitro, sieving coefficient data are often used as a predictor of the clinical performance of dialyzers. Although standards for the measurement of sieving coefficients exist, the stated methodologies do not offer sufficient guidance to ensure comparability of test results between different dialyzers. The aim of this work was to investigate the relationship between sieving coefficients and published clinical performance indicators for two solutes, albumin loss and beta‐2 microglobulin (β2M) reduction ratio (RR), and to assess the impact of different in vitro test parameters on sieving coefficient values for albumin, β2M, and myoglobin. Clinical albumin loss and β2M RR for commercially available dialyzers used in hemodialysis (HD) and post‐dilution hemodiafiltration (HDF) were extracted from the literature and plotted against sieving coefficients reported in data sheets and IFUs. Albumin, β2M, and myoglobin sieving coefficients of a selection of dialyzers were measured per the ISO 8637 standard. The impact of in vitro testing conditions was assessed by changing blood flow rate, ultrafiltration (UF) rate, sampling time, and origin of test plasma. Results showed variation in albumin loss and β2M RR for the same sieving coefficient across different dialyzers in HD and HDF. Changes in blood flow rates, UF rates, sampling time, and test plasma (bovine vs. human) caused marked differences in sieving coefficient values for all investigated solutes. When identical testing conditions were used, sieving coefficient values for the same dialyzer were reproducible. Testing conditions have a marked impact on the measurement of sieving coefficients, and values should not be compared unless identical conditions are used. Further, variability in observed clinical data in part reflects the lack of definition of test conditions.
Sprache
Englisch
Identifikatoren
ISSN: 0160-564X
eISSN: 1525-1594
DOI: 10.1111/aor.13278
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6585607

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX