Neurogastroenterology and motility, 2015-02, Vol.27 (2), p.277-284
2015

Details

Autor(en) / Beteiligte
Titel
Determinants of pressure drift in Manoscan™ esophageal high‐resolution manometry system
Ist Teil von
  • Neurogastroenterology and motility, 2015-02, Vol.27 (2), p.277-284
Ort / Verlag
England: Wiley Subscription Services, Inc
Erscheinungsjahr
2015
Link zum Volltext
Quelle
Wiley Online Library
Beschreibungen/Notizen
  • Background Manoscan™ is one of the commonly used high‐resolution manometry (HRM) systems with declared measurement accuracy of 1–2 mmHg. However, the accuracy of pressure measurements is limited by development of pressure drift (PD) throughout recording. To date, there has been no systematic investigation to identify the factors contributing to PD. The aim of the present study was to characterize the frequency and magnitude of PD in Manoscan™ system and identify the factors contributing to PD. Methods Records of 560 consecutive clinical esophageal HRM studies recorded by six distinct HRM catheters were retrospectively reviewed. PD was defined as the residual pressure measurement by each sensor immediately after removal of the catheter. Non‐parametric locally weighted regression analysis was performed to assess the effect of duration of study, number of prior uses of a catheter, peak and average pressure exposure during a study on the PD. Key Results The majority (95%) of clinical manometry studies showed a non‐negligible PD of more than 5 mmHg. The overall PD was 13 ± 5 mmHg and the sensor with greatest amount of PD showed 23 ± 12 mmHg of drift. The upper esophageal sphincter showed the highest PD. Average pressure exposure of a sensor throughout the recording was the most important predictor of PD. PD inversely correlated with number of prior uses of a catheter. Conclusions & Inferences The PD preferentially affects esophageal high‐pressure zones, and strongly correlates with ‘average pressure exposure’ of a sensor during manometry. Available algorithms of the analysis software do not adequately correct the PD. The majority (95%) of clinical manometry studies performed with Manoscan™ system show a non‐negligible pressure drift (PD) of more than 5 mmHg. PD preferentially affects esophageal sphincter high‐pressure zones, and strongly correlates with ‘average pressure exposure’ of a sensor during manometry. ‘Thermal compensation’ algorithm does not adequately address the PD, and future studies are needed to develop more precise corrective algorithms.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX