Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...

Details

Autor(en) / Beteiligte
Titel
A semi-automated solid-phase extraction liquid chromatography/tandem mass spectrometry method for the analysis of tetrahydrocannabinol and metabolites in whole blood
Ist Teil von
  • Rapid communications in mass spectrometry, 2009-09, Vol.23 (17), p.2697-2705
Ort / Verlag
Chichester, UK: John Wiley & Sons, Ltd
Erscheinungsjahr
2009
Link zum Volltext
Quelle
Wiley Online Library Journals Frontfile Complete
Beschreibungen/Notizen
  • Marijuana is one of the most commonly abused illicit substances in the USA, making cannabinoids important to detect in clinical and forensic toxicology laboratories. Historically, cannabinoids in biological fluids have been derivatized and analyzed by gas chromatography/mass spectrometry (GC/MS). There has been a gradual shift in many laboratories towards liquid chromatography/mass spectrometry (LC/MS) for this analysis due to its improved sensitivity and reduced sample preparation compared with GC/MS procedures. This paper reports a validated method for the analysis of Δ9‐tetrahydrocannabinol (THC) and its two main metabolites, 11‐nor‐9‐carboxy‐Δ9‐tetrahydrocannabinol (THC‐COOH) and 11‐hydroxy‐Δ9‐tetrahydrocannabinol (THC‐OH), in whole blood samples. The method has also been validated for cannabinol (CBD) and cannabidiol (CDN), two cannabinoids that were shown not to interfere with the method. This method has been successfully applied to samples both from living people and from deceased individuals obtained during autopsy. This method utilizes online solid‐phase extraction (SPE) with LC/MS. Pretreatment of samples involves protein precipitation, sample concentration, ultracentrifugation, and reconstitution. The online SPE procedure was developed using Hysphere C8‐EC sorbent. A chromatographic gradient with an Xterra MS C18 column was used for the separation. Four multiple‐reaction monitoring (MRM) transitions were monitored for each analyte and internal standard. Linearity generally fell between 2 and 200 ng/mL. The limits of detection (LODs) ranged from 0.5 to 3 ng/mL and the limits of quantitation (LOQs) ranged from 2 to 8 ng/mL. The bias and imprecision were determined using a simple analysis of variance (ANOVA: single factor). The results demonstrate bias as <7%, and imprecision as <9%, for all components at each quantity control level. Published in 2009 by John Wiley & Sons, Ltd.
Sprache
Englisch
Identifikatoren
ISSN: 0951-4198
eISSN: 1097-0231
DOI: 10.1002/rcm.4174
Titel-ID: cdi_crossref_primary_10_1002_rcm_4174

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX