Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 20 von 65

Details

Autor(en) / Beteiligte
Titel
Combined application of virtual imaging techniques and three-dimensional computed tomographic angiography in diagnosing intracranial aneurysms
Ist Teil von
  • Chinese medical journal, 2008-12, Vol.121 (24), p.2521-2524
Ort / Verlag
China: Department of Neurosurgery, Neurosurgery Institute of Guangdong Province Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong 510282, China%Department of Diagnostic Radiology Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong 510282, China%3 Volume Interactions Pte Ltd, 1 Kim Seng Promenade, #12-01,Great World City East Tower, 237994, Singapore
Erscheinungsjahr
2008
Link zum Volltext
Quelle
Free E-Journal (出版社公開部分のみ)
Beschreibungen/Notizen
  • Background The diagnostic value of virtual imaging combined with three-dimensional computed tomographic angiography (3D-CTA) for intracranial aneurysms has not been fully elucidated yet. This study aimed to evaluate the value of combined application of virtual imaging techniques and 3D-CTA in diagnosing patients with aneurismal subarachnoid hemorrhage (SAH) at the acute stage. Methods Eighty patients with non-traumatic SAH received 3D-CTA examinations. The raw CT data of these patients were reconstructed and transferred into the 3D mode through the surgical plan system based on virtual reality (VR) image, and the 3D virtual images of skulls and brain blood vessels were acquired. The location, size and shape of aneurysms and their anatomic relationship with adjacent tissues were measured from many points of view. Results Seventy-three aneurysms were detected in 68 of the 80 patients, but 2 aneurysms were detected in 2 of the 5 patients who had been found free of aneurysms previously and had received 3D-CTA examinations for a second time one month later. The 3D virtual images produced by the virtual imaging system were clear and vivid, and they could reveal the location and size of the aneurysm and its relations to the parent artery and skull directly. Conclusions The imaging of 3D-CTA is convenient, reliable and fast in diagnosing intracranial aneurysms and can be regarded as the first choice for the diagnosis and treatment of ruptured intracranial aneurysms. Combined with the surgical plan system based on the VR image, 3D-CTA may obtain more imaging information about aneurysms.
Sprache
Englisch
Identifikatoren
ISSN: 0366-6999
eISSN: 2542-5641
DOI: 10.1097/00029330-200812020-00010
Titel-ID: cdi_wanfang_journals_zhcmj200824010

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX