Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 10 von 1035

Details

Autor(en) / Beteiligte
Titel
Comparing the Efficacy of Radiation Free Machine-Vision Image-Guided Surgery With Traditional 2-Dimensional Fluoroscopy: A Randomized, Single-Center Study
Ist Teil von
  • HSS journal, 2021-10, Vol.17 (3), p.274-280
Ort / Verlag
Los Angeles, CA: SAGE Publications
Erscheinungsjahr
2021
Link zum Volltext
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Background: Three-dimensional (3D) computer-assisted navigation (CAN) has emerged as a potential alternative to 2-dimensional (2D) fluoroscopy in the surgical placement of spinal instrumentation. Recently, 3D-CAN systems have improved significantly in their ability to provide real-time anatomical referencing while shortening the registration and set-up time. A novel system in navigation, Machine-Vision Image-Guided Surgery (MvIGS; 7D Surgical, Toronto, Canada) was cleared by the US Food and Drug Administration, but its potential benefits in reducing intra-operative radiation exposure to patients and enhancing surgical accuracy of pedicle screw placement are not fully known. Purpose: We sought to conduct a prospective, randomized, clinical study comparing the 3D-MvIGS spinal navigation system and 2D-fluoroscopy for pedicle screw insertion up to 3 levels (T10-S1) and for various measures of surgical efficacy. Methods: Sixty-two eligible patients were randomized to receive spine surgery using either the 3D-MvIGS group or the conventional 2D-fluoroscopy for pedicle screw fixation for the treatment of spinal stenosis and degenerative spondylolisthesis. Intra-operative parameters and procedure-related unintended protocol violations were recorded. Results: Operative time and estimated blood loss were not significantly different between groups. Radiation time and exposure to patients were significantly reduced in the 3D-MvIGS group. There was no difference between groups in pedicle screw placement accuracy (2D-fluoroscopy group, 96.6%; 3D-MvIGS group, 94.2%). There were no major complications or cases that required revision surgery. Conclusion: The 3D-MvIGS navigation system performed comparably with 2D-fluoroscopy in terms of pedicle screw placement accuracy and operative time. The 3D-MvIGS showed a significant reduction in radiation exposure to patients. In more complex cases or larger cohorts, the true value of greater anatomical visualization can be elucidated.
Sprache
Englisch
Identifikatoren
ISSN: 1556-3316
eISSN: 1556-3324
DOI: 10.1177/15563316211029837
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8436349
Format
Schlagworte
Original

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX