Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 17 von 32

Details

Autor(en) / Beteiligte
Titel
Learning Image Quality Assessment by Reinforcing Task Amenable Data Selection
Ist Teil von
  • Information Processing in Medical Imaging, p.755-766
Ort / Verlag
Cham: Springer International Publishing
Link zum Volltext
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • In this paper, we consider a type of image quality assessment (IQA) as a task-specific measurement, which can be used to select images that are more amenable to a given target task, such as image classification or segmentation. We propose to train simultaneously two neural networks for image selection and a target task using reinforcement learning. A controller network learns an image selection policy by maximising an accumulated reward based on the target task performance on the controller-selected validation set, whilst the target task predictor is optimised using the training set. The trained controller is therefore able to reject images that lead to poor accuracy in the target task. In this work, we show that controller-predicted IQA can be significantly different from task-specific quality labels manually defined by humans. Furthermore, we demonstrate that it is possible to learn effective IQA without a “clean” validation set, thereby avoiding the requirement for human labels of task amenability. Using 6712, labelled and segmented, clinical ultrasound images from 259 patients, experimental results on holdout data show that the proposed IQA achieved a mean classification accuracy of 0.94±0.01\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$0.94\pm 0.01$$\end{document} and a mean segmentation Dice of 0.89±0.02\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$0.89\pm 0.02$$\end{document}, by discarding 5%\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$5\%$$\end{document} and 15%\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$15\%$$\end{document} of the acquired images, respectively. The significantly improved performance was observed for both tested tasks, compared with the respective 0.90±0.01\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$0.90\pm 0.01$$\end{document} and 0.82±0.02\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$0.82\pm 0.02$$\end{document} from networks without considering task amenability. This enables IQA feedback during real-time ultrasound acquisition among many other medical imaging applications.
Sprache
Englisch
Identifikatoren
ISBN: 3030781909, 9783030781903
ISSN: 0302-9743
eISSN: 1611-3349
DOI: 10.1007/978-3-030-78191-0_58
Titel-ID: cdi_springer_books_10_1007_978_3_030_78191_0_58

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX