Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 12 von 1241

Details

Autor(en) / Beteiligte
Titel
TH‐D‐224C‐09: Implementation of the Varian Eclipse System for Proton Therapy Treatment Planning
Ist Teil von
  • Medical Physics, 2006-06, Vol.33 (6), p.2284-2284
Ort / Verlag
American Association of Physicists in Medicine
Erscheinungsjahr
2006
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Purpose: To configure and test a treatment planning system (TPS) (Varian, Palo Alto) for use with a passively‐scattered proton therapy delivery system. Methods and Materials: Since the mechanical designs of the commercial beam delivery apparatus (Probeat, Hitachi Limited, Japan) had not yet been completed, measurements of the required data were not possible. Instead, we designed our own therapy system components using analytical methods. The MCNPX (Los Alamos National Laboratory) Monte Carlo (MC) code was used to simulate beam profiles. Separate codes were developed to create the initial proton sources, the absorbed dose and fluence tallies, and simple homogeneous water phantoms (see Zheng et al., separate contribution). Up to 108 proton histories were tracked per simulation to achieve < 2% statistical uncertainties. Additional codes were developed to generate ancillary TPS configuration files, e.g., for the range modulator wheels, flattening filters, and variable range shifter. The MC beam characteristics such as penetration range were compared with values from independent one‐dimensional analytical calculations. Results: A complete set of configuration parameters and beam profiles were generated, including 832 dose and fluence profiles, in approximately four weeks (simulation time using 60 CPUs). With the simulated configuration data, the TPS has undergone extensive development and testing during the past year. Preliminary results indicate that the MC, TPS, and independent analytical calculations are in good agreement (< 4 mm differences in penetration range). Conclusion: The results of this study demonstrate the practicality of MC models to calculate beam data for configuring a proton treatment planning system. Additional simulations with the manufacturer's preliminary equipment designs are now in progress. Validation tests of Eclipse in heterogeneous media are in progress (see Titt et al., separate contribution). Confirmatory measurements are planned. Conflict of Interest: This work was funded in part by a research grant from Varian.
Sprache
Englisch
Identifikatoren
ISSN: 0094-2405
eISSN: 2473-4209
DOI: 10.1118/1.2241921
Titel-ID: cdi_scitation_primary_10_1118_1_2241921

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX