Analysis of the concordance rates between core needle biopsy and surgical excision in patients with breast cancer
Ist Teil von
  • Revista da Associacao Medica Brasileira (1992), 2012-09, Vol.58 (5), p.532-536
Ort / Verlag
Brazil: Elsevier Editora Ltda
Erscheinungsjahr
2012
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • To evaluate whether immunohistochemical marker studies performed on core needle biopsy (CNB) specimens accurately reflect the marker status of the tumor obtained from final surgical specimen. This was a retrospective study that used the database of the Division of Mastology of the Hospital das Clínicas, São Paulo, Brazil. Sixty-nine patients submitted to ultrasound-guided CNB diagnosed with breast cancer were retrospectively analyzed. Immunohistochemistry (IHC) on core biopsy specimens was compared to that of excisional biopsy regarding estrogen receptor (ER), progesterone receptor (PR), human epidermal gowth factor receptor 2 gene (HER2), p53, and Ki67. The analysis of the concordance between CNB and surgical biopsy was performed using the kappa (k) coefficient (95% CI). A perfect concordance between the labeling in the surgical specimens and the preoperative biopsies in p53 (k=1.0; 95% CI: 0.76–1.0) was identified. There was an almost perfect concordance for ER (k=0.89; 95% CI: 0.65–1.0) and a substantial concordance for PR (k=0.70; 95% CI: 0.46–0.93). HER2 (k=0.61; 95% CI: 0.38–0.84) and Ki-67 (k=0.74; 95% CI: 0.58–0.98) obtained a substantial concordance this analysis. The results of this study indicate that the immunohistochemical analysis of ER, PR, Ki-67, and p53 from core biopsy specimens provided results that accurately reflect the marker status of the tumor. The concordance rate of HER2 was less consistent; although it produced substantial concordance, values were very close to moderate concordance. Avaliar se a análise dos marcadores imunoistoquímicos obtidos por meio de espécimes de core biopsy (CB) refletem com precisão o perfil dos marcadores tumorais obtidos por biópsia cirúrgica excisional (BCE). Estudo retrospectivo usando dados da Divisão de Mastologia do Hospital das Clínicas de São Paulo. Sessenta e nove pacientes submetidas à CB guiada por ultrassom com diagnóstico de câncer de mama foram analisadas retrospectivamente. O exame imunoistoquímico dos espécimes de CB foram comparados com aquele obtido a partir da BCE em relação ao receptor de estrogênio (RE), receptor de progesterona (RP), human epidermal gowth factor receptor 2 gene (HER2), p53 e Ki-67. A análise de concordância entre a CB e a BCE foram realizados usando o coeficiente de kappa (k) (IC 95%). A concordância perfeita entre a BCE e a CB do p53 (k=1,0; IC 95%: 0,76–1,0) foi identificada. A concordância foi quase perfeita para o RE (k=0,89; IC 95%: 0,65–1,0) e concordância substancial foi identificada para o RP (= 0,70; IC 95%: 0,46–0,93). O HER2 (k=0,61; IC 95%: 0,38–0,84) e Ki-67 (k=0,74; IC 95%: 0,58–0,98) obtiveram uma concordância substancial nesta análise. os resultados deste estudo indicam que a análise imunoistoquímica do RE, RP, Ki-67 e p53 a partir dos espécimes de CB fornecem resultados que refletem com precisão o perfil dos marcadores do tumor. O HER2 foi menos consistente, porque apesar de ter produzido uma concordância substancial, os valores foram muito próximos da concordância moderada.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX