Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 12 von 38

Details

Autor(en) / Beteiligte
Titel
Extending the capabilities of field flow fractionation online with ICP-MS for the determination of particulate carbon in latex and charcoalElectronic supplementary information (ESI) available. See DOI: 10.1039/c8ja00101d
Erscheinungsjahr
2018-08
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • There is a broad range of carbon based engineered particles including polymer latex particles and carbon black. Also in environmental systems particulate carbon such as humic acids and soot or coal (the latter two summarized as black carbon) is of great importance and is involved in nutrient storage and (re)cycling. Therefore, detailed characterisation of the size distribution and elemental composition of such particles is required to understand the material properties and their environmental relevance. Field flow fractionation (FFF) online with inductively coupled plasma mass spectrometry (ICP-MS) is routinely applied for the characterisation of metal containing particles. However, the far majority of FFF studies relies on UV detection for organic carbon while elemental detection of carbon has hardly been used. Our previous work demonstrated the capability of FFF-ICP-MS for the determination of carbon in fine particulate matter, focusing on humic acid in water samples. The current work investigates the feasibility of carbon detection and quantification in larger particles with sizes up to about 750 nm. For this purpose, latex particle size standards of 21 nm, 100 nm, 250 nm and 740 nm were analysed as well as extracts of charcoal spiked soil. Elemental analysis using combustion techniques was employed as reference for the total carbon content of the samples to establish a mass balance. Recoveries for FFF separation of latex particle standards were in the range from 69% to 83% and in the range from 78% to 104% in flow injection mode. Carbon mass balance calculated from FFF fractionation, ultrafiltration and total content for the extracts from soil and charcoal spiked soil achieved 76% to 105%. Variation of the sampling depth was investigated to check if increased dwell time of the particles in the plasma affects the carbon ionisation and quantification. No significant change of carbon recoveries was observed, yet the signal to noise ratio improved 3-fold. This study provides a method for the analyses of carbon containing particles via FFF-ICP-MS, which allows for the first time the simultaneous measurement of carbon and other nutrients and is hence more timesaving than other methods. Redefinition of ICP-MS as inorganic/metal, carbon and phosphorus detector online with field-flow-fractionation with focus on particulate carbon in this study.
Sprache
Englisch
Identifikatoren
ISSN: 0267-9477
eISSN: 1364-5544
DOI: 10.1039/c8ja00101d
Titel-ID: cdi_rsc_primary_c8ja00101d
Format

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX