Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 2 von 34

Details

Autor(en) / Beteiligte
Titel
Validation of 18F-rhPSMA-7 and 18F-rhPSMA-7.3 PET Imaging Results with Histopathology from Salvage Surgery in Patients with Biochemical Recurrence of Prostate Cancer
Ist Teil von
  • The Journal of nuclear medicine (1978), 2022-12, Vol.63 (12), p.1809-1814
Ort / Verlag
New York: Society of Nuclear Medicine
Erscheinungsjahr
2022
Link zum Volltext
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • 18F-rhPSMA-7, and its single diastereoisomer form, 18F-rhPSMA-7.3, are prostate-specific membrane antigen (PSMA)–targeting radiopharmaceuticals. Here, we investigated their accuracy for the assessment of lymph node (LN) metastases validated by histopathology. Methods: Data from 58 patients with biochemical recurrence of prostate cancer after radical prostatectomy receiving salvage surgery after PET imaging with 18F-rhPSMA-7 or 18F-rhPSMA-7.3 were retrospectively reviewed. Two nuclear medicine physicians reviewed all PET scans and morphologic imaging in consensus. Readers were masked from the results of histopathology. PET and morphologic imaging were correlated with histopathology from resected LNs. Results: In 75 of 150 resected regions in 54 of 58 patients, tumor lesions were present in histopathology. The template-based specificity of PET (18F-rhPSMA-7 and 18F-rhPSMA-7.3 combined) and morphologic imaging was 93.3% and 100%, respectively. However, 18F-rhPSMA-7 and 18F-rhPSMA-7.3 PET detected metastases in 61 of 75 histopathologically proven metastatic LN fields (81.3%) whereas morphologic imaging was positive in only 9 of 75 (12.0%). The positive predictive value was 92.4% for 18F-rhPSMA-7 and 18F-rhPSMA-7.3 PET and 100% for morphologic imaging. 18F-rhPSMA-7 and 18F-rhPSMA-7.3 PET performance was significantly superior to morphologic imaging (difference in the areas under the receiver-operating-characteristic curves, 0.222; 95% CI, 0.147–0.298; P < 0.001). The mean size of PET-positive and histologically confirmed LN metastases was 6.3 ± 3.1 mm (range, 2–15 mm) compared with a mean size of 9.8 ± 2.5 mm (range, 7–15 mm) on morphologic imaging. Conclusion: 18F-rhPSMA-7 and 18F-rhPSMA-7.3 PET offer a high positive predictive value comparable to that reported for 68Ga-PSMA-11 and represent a valuable tool for guiding salvage lymphadenectomy.
Sprache
Englisch
Identifikatoren
ISSN: 0161-5505
eISSN: 1535-5667
DOI: 10.2967/jnumed.121.263707
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_9730917

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX