Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 22 von 537

Details

Autor(en) / Beteiligte
Titel
Seizure forecasting using minimally invasive, ultra-long-term subcutaneous EEG: Generalizable cross-patient models
Ist Teil von
  • Epilepsia (Copenhagen), 2023-12, Vol.64 Suppl 4 (S4), p.S114-S123
Ort / Verlag
United States: Wiley Subscription Services, Inc
Erscheinungsjahr
2023
Quelle
Wiley Online Library Journals【Remote access available】
Beschreibungen/Notizen
  • This study describes a generalized cross-patient seizure-forecasting approach using recurrent neural networks with ultra-long-term subcutaneous EEG (sqEEG) recordings. Data from six patients diagnosed with refractory epilepsy and monitored with an sqEEG device were used to develop a generalized algorithm for seizure forecasting using long short-term memory (LSTM) deep-learning classifiers. Electrographic seizures were identified by a board-certified epileptologist. One-minute data segments were labeled as preictal or interictal based on their relationship to confirmed seizures. Data were separated into training and testing data sets, and to compensate for the unbalanced data ratio in training, noise-added copies of preictal data segments were generated to expand the training data set. The mean and standard deviation (SD) of the training data were used to normalize all data, preserving the pseudo-prospective nature of the analysis. Different architecture classifiers were trained and tested using a leave-one-patient-out cross-validation method, and the area under the receiver-operating characteristic (ROC) curve (AUC) was used to evaluate the performance classifiers. The importance of each input signal was evaluated using a leave-one-signal-out method with repeated training and testing for each classifier. Cross-patient classifiers achieved performance significantly better than chance in four of the six patients and an overall mean AUC of 0.602 ± 0.126 (mean ± SD). A time in warning of 37.386% ± 5.006% (mean ± std) and sensitivity of 0.691 ± 0.068 (mean ± std) were observed for patients with better than chance results. Analysis of input channels showed a significant contribution (p < .05) by the Fourier transform of signals channels to overall classifier performance. The relative contribution of input signals varied among patients and architectures, suggesting that the inclusion of all signals contributes to robustness in a cross-patient classifier. These early results show that it is possible to forecast seizures training with data from different patients using two-channel ultra-long-term sqEEG.
Sprache
Englisch
Identifikatoren
ISSN: 0013-9580
eISSN: 1528-1167
DOI: 10.1111/epi.17265
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_9582039

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX