Usefulness of maximum intensity projection images of non-enhanced CT for detection of hyperdense middle cerebral artery sign in acute thromboembolic ischemic stroke
Ist Teil von
Japanese journal of radiology, 2022-10, Vol.40 (10), p.1046-1052
Ort / Verlag
Singapore: Springer Nature Singapore
Erscheinungsjahr
2022
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
Purpose
To compare the sensitivity of the hyperdense middle cerebral artery (MCA) sign between maximum intensity projection (MIP) and conventional averaged images in patients with acute focal neurological deficits with acute thromboembolic MCA occlusion (MCA occlusion group) and patients with acute focal neurological deficits without MCA occlusion (control group).
Materials and methods
Initial computed tomography (CT) scans on admission were reconstructed with 5 mm thickness at every 3 mm interval for averaged and MIP images from 1 mm thickness non-contrast axial source images. Images were obtained from 30 cases each in the MCA occlusion and control groups. The CT values in the region of interests (ROIs) on the affected and unaffected sides of the MCA were compared. To compare CT values among subjects, the CT values were normalized by obtaining a ratio on the affected and unaffected sides, and the normalized CT values were analyzed using the receiver operating characteristic (ROC) curve.
Results
The hyperdense MCA sign was visually detected on MIP images in 90% cases and on 5 mm averaged images in only 57% cases in the MCA occlusion group. Based on the ROC analysis of the normalized ratio on the affected and unaffected sides, area under the curve of MIP image and averaged image was 0.941 and 0.655, respectively. On MIP images, the optimal threshold of the ratio on the affected and unaffected sides was 1.152 (sensitivity: 90.0%, and specificity: 93.3%).
Conclusion
The hyperdense MCA sign sensitivity on 5 mm MIP images was significantly higher than that on conventional 5 mm averaged CT images. This could be useful for the early initiation of proper therapy for patients with acute focal neurological deficits.