Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 8 von 821

Details

Autor(en) / Beteiligte
Titel
Usefulness of maximum intensity projection images of non-enhanced CT for detection of hyperdense middle cerebral artery sign in acute thromboembolic ischemic stroke
Ist Teil von
  • Japanese journal of radiology, 2022-10, Vol.40 (10), p.1046-1052
Ort / Verlag
Singapore: Springer Nature Singapore
Erscheinungsjahr
2022
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Purpose To compare the sensitivity of the hyperdense middle cerebral artery (MCA) sign between maximum intensity projection (MIP) and conventional averaged images in patients with acute focal neurological deficits with acute thromboembolic MCA occlusion (MCA occlusion group) and patients with acute focal neurological deficits without MCA occlusion (control group). Materials and methods Initial computed tomography (CT) scans on admission were reconstructed with 5 mm thickness at every 3 mm interval for averaged and MIP images from 1 mm thickness non-contrast axial source images. Images were obtained from 30 cases each in the MCA occlusion and control groups. The CT values in the region of interests (ROIs) on the affected and unaffected sides of the MCA were compared. To compare CT values among subjects, the CT values were normalized by obtaining a ratio on the affected and unaffected sides, and the normalized CT values were analyzed using the receiver operating characteristic (ROC) curve. Results The hyperdense MCA sign was visually detected on MIP images in 90% cases and on 5 mm averaged images in only 57% cases in the MCA occlusion group. Based on the ROC analysis of the normalized ratio on the affected and unaffected sides, area under the curve of MIP image and averaged image was 0.941 and 0.655, respectively. On MIP images, the optimal threshold of the ratio on the affected and unaffected sides was 1.152 (sensitivity: 90.0%, and specificity: 93.3%). Conclusion The hyperdense MCA sign sensitivity on 5 mm MIP images was significantly higher than that on conventional 5 mm averaged CT images. This could be useful for the early initiation of proper therapy for patients with acute focal neurological deficits.
Sprache
Englisch
Identifikatoren
ISSN: 1867-1071
eISSN: 1867-108X
DOI: 10.1007/s11604-022-01289-8
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_9529686

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX