Real‐time 3D motion estimation from undersampled MRI using multi‐resolution neural networks
Ist Teil von
  • Medical physics (Lancaster), 2021-11, Vol.48 (11), p.6597-6613
Ort / Verlag
Hoboken: John Wiley and Sons Inc
Erscheinungsjahr
2021
Quelle
Wiley-Blackwell Journals
Beschreibungen/Notizen
  • Purpose: To enable real‐time adaptive magnetic resonance imaging–guided radiotherapy (MRIgRT) by obtaining time‐resolved three‐dimensional (3D) deformation vector fields (DVFs) with high spatiotemporal resolution and low latency (<500 ms). Theory and Methods: Respiratory‐resolved T1‐weighted 4D‐MRI of 27 patients with lung cancer were acquired using a golden‐angle radial stack‐of‐stars readout. A multiresolution convolutional neural network (CNN) called TEMPEST was trained on up to 32× retrospectively undersampled MRI of 17 patients, reconstructed with a nonuniform fast Fourier transform, to learn optical flow DVFs. TEMPEST was validated using 4D respiratory‐resolved MRI, a digital phantom, and a physical motion phantom. The time‐resolved motion estimation was evaluated in‐vivo using two volunteer scans, acquired on a hybrid MR‐scanner with integrated linear accelerator. Finally, we evaluated the model robustness on a publicly‐available four‐dimensional computed tomography (4D‐CT) dataset. Results: TEMPEST produced accurate DVFs on respiratory‐resolved MRI at 20‐fold acceleration, with the average end‐point‐error <2 mm, both on respiratory‐sorted MRI and on a digital phantom. TEMPEST estimated accurate time‐resolved DVFs on MRI of a motion phantom, with an error <2 mm at 28× undersampling. On two volunteer scans, TEMPEST accurately estimated motion compared to the self‐navigation signal using 50 spokes per dynamic (366× undersampling). At this undersampling factor, DVFs were estimated within 200 ms, including MRI acquisition. On fully sampled CT data, we achieved a target registration error of 1.87±1.65 mm without retraining the model. Conclusion: A CNN trained on undersampled MRI produced accurate 3D DVFs with high spatiotemporal resolution for MRIgRT.
Sprache
Englisch
Identifikatoren
ISSN: 0094-2405
eISSN: 2473-4209
DOI: 10.1002/mp.15217
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_9298075

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX