Bipolar ablation of therapy-refractory ventricular arrhythmias: application of a dedicated approach
Ist Teil von
  • Europace (London, England), 2022-07, Vol.24 (6), p.959-969
Ort / Verlag
England: Oxford University Press
Erscheinungsjahr
2022
Quelle
Oxford Journals 2020 Medicine
Beschreibungen/Notizen
  • Bipolar radiofrequency ablation (B-RFA) has been reported as a bail-out strategy for the treatment of therapy refractory ventricular arrhythmias (VA). Currently, existing setups have not been standardized for B-RFA, while the impact of conventional B-RFA approaches on lesion formation remains unclear. (i) In a multicentre observational study, patients undergoing B-RFA for previously therapy-refractory VA using a dedicated B-RFA setup were retrospectively analysed. (ii) Additionally, in an ex vivo model lesion formation during B-RFA was evaluated using porcine hearts. In a total of 26 procedures (24 patients), acute success was achieved in all 14 ventricular tachycardia (VT) procedures and 7/12 procedures with premature ventricular contractions (PVC), with major complications occurring in 1 procedure (atrioventricular block). During a median follow-up of 211 days in 21 patients, 6/11 patients (VT) and 5/10 patients (PVC) remained arrhythmia-free. Lesion formation in the ex vivo model during energy titration from 30 to 50 W led to similar lesion volumes compared with initial high-power 50 W B-RFA. Lesion size significantly increased when combining sequential unipolar and B-RFA (1429 mm3 vs. titration 501 mm3 vs. B-RFA 50 W 423 mm3, P < 0.001), an approach used in overall 58% of procedures and more frequently applied in procedures without VA recurrence (92% vs. 36%, P = 0.009). Adipose tissue severely limited lesion formation during B-RFA. Using a dedicated device for B-RFA for therapy-refractory VA appears feasible and safe. While some patients need repeat ablation, success rates were encouraging. Sequential unipolar and B-RFA may be favourable for lesion formation.
Sprache
Englisch
Identifikatoren
ISSN: 1099-5129
eISSN: 1532-2092
DOI: 10.1093/europace/euab304
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_9282917

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX