Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 7 von 94
International ophthalmology, 2022-07, Vol.42 (7), p.2029-2038
2022
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Comparison of accuracy of intraocular lens power calculation for eyes with an axial length greater than 29.0 mm
Ist Teil von
  • International ophthalmology, 2022-07, Vol.42 (7), p.2029-2038
Ort / Verlag
Dordrecht: Springer Netherlands
Erscheinungsjahr
2022
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Purpose To evaluate and compare the accuracy of six different formulas (Emmetropia Verifying Optical version 2.0, Kane, SRK/T, Barrett Universal II, Haigis and Olsen) in intraocular lens (IOL) power calculation for extremely long eyes. Methods Retrospective case-series. Seventy-three eyes with axial length (AL) ≥ 29.0 mm and underwent phacoemulsification cataract surgery with Rayner (Hove, UK) 920H IOL implantation from January 2018 to March 2020 were included. Prediction errors (PE) were calculated and compared between different formulas to evaluate the accuracy of formulas. Multiple regression analysis was performed to investigate factors associated with the PE. Results The Kane formula had mean prediction error close to zero (– 0.01 ± 0.51 D, P  = 0.841), whereas the EVO 2.0, SRK/T, Barrett Universal II, Haigis and Olsen formulas produced hyperopic outcomes (all P  < 0.001). The median absolute error [inter-quartile range] produced by the EVO 2.0, Kane, Barrett Universal II and Olsen formulas showed no significant difference (0.33 D [0.48], 0.30 D [0.44], 0.34 D [0.39], 0.29 D [0.37], respectively, pairwise comparison P  > 0.05), but was significantly lower than that of the SRK/T and Haigis formulas (0.85 D [0.66], 0.80 D [0.54], respectively, pairwise comparison P  < 0.001). The AL and the PE produced by the SRK/T formula were significantly positively correlated in extremely myopic eyes ( β  = 0.248, P  < 0.001), whereas the trend was not demonstrated in other formulas. Conclusions For cataract patients with axial length greater than 29.0 mm, the accuracy of the EVO 2.0, Kane, Barrett Universal II and Olsen formulas is comparable and significantly better than that of the SRK/T and Haigis formulas.
Sprache
Englisch
Identifikatoren
ISSN: 1573-2630, 0165-5701
eISSN: 1573-2630
DOI: 10.1007/s10792-021-02194-1
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_9085560

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX