Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 14 von 5079
American journal of neuroradiology : AJNR, 2021-11, Vol.42 (11), p.2016-2022
2021
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Measuring 3D Cochlear Duct Length on MRI: Is It Accurate and Reliable?
Ist Teil von
  • American journal of neuroradiology : AJNR, 2021-11, Vol.42 (11), p.2016-2022
Ort / Verlag
American Society of Neuroradiology
Erscheinungsjahr
2021
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • BACKGROUND AND PURPOSEPrior studies have evaluated cochlear length using CT to select the most suitable cochlear implants and obtain patient-specific anatomy. This study aimed to test the accuracy and reliability of cochlear lateral wall length measurements using 3D MR imaging. MATERIALS AND METHODSTwo observers measured the cochlear lateral wall length of 35 patients (21 men) with postlingual hearing loss using CT and MR imaging. The intraclass correlation coefficient (with 95% confidence intervals) was used to evaluate intraobserver and interobserver reliability for the 3D cochlear measurements. RESULTSThe mean age of the participants was 39.85 (SD, 16.60) years. Observer 1 measured the mean lateral wall length as 41.52 (SD, 2.25) mm on CT and 41.44 (SD, 2.18) mm on MR imaging, with a mean difference of 0.08 mm (95% CI, -0.11 to 0.27 mm), while observer 2 measured the mean lateral wall length as 41.74 (SD, 2.69) mm on CT and 42.34 (SD, 2.53) mm on MR imaging, with a mean difference of -0.59 mm (95% CI, -1.00 to -0.20 mm). An intraclass correlation coefficient value of 0.90 (95% CI, 0.84-0.94) for CT and 0.69 (95% CI, 0.46-0.82) for MR imaging was obtained for the interobserver reliability for the full-turn cochlear lateral wall length. CONCLUSIONSCT-based 3D cochlear measurements show excellent intraobserver and interobserver reliability, while MR imaging-based lateral wall length measurements have good-to-excellent intraobserver reliability and moderate interobserver reliability. These results corroborate the use of CT for 3D cochlear measurements as a reference method and demonstrate MR imaging to be an alternative acquisition technique with comparably reliable results.
Sprache
Englisch
Identifikatoren
ISSN: 0195-6108
eISSN: 1936-959X
DOI: 10.3174/ajnr.A7287
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8583280
Format
Schlagworte
Head & Neck

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX