Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 16 von 123
Asian journal of neurosurgery, 2020-07, Vol.15 (3), p.620-626
2020
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
The exchange-free technique: A novel technique for enhancing surpass flow diverter placement
Ist Teil von
  • Asian journal of neurosurgery, 2020-07, Vol.15 (3), p.620-626
Ort / Verlag
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India: Thieme Medical and Scientific Publishers Pvt. Ltd
Erscheinungsjahr
2020
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • Background: Following flow diverter placement, approximately 20% of intracranial aneurysms remain as residual aneurysms at 1 year. Device malapposition is a cause of residual aneurysms after flow diversion. We present a new and straightforward technique (exchange-free technique [EFT]) to enhance apposition of the surpass flow diverter (SFD), the only over-the-wire flow diverter currently available. Materials and Methods: We deployed laser-cut mini stents through the inner deployment catheter of the SFD. This maneuver was performed simply by withdrawing the micro-guidewire from its lumen and replacing it with a mini-stent (stents deliverable through microcatheters with inner diameter of 0.0165 inches), without a need to re-cross the deployed SFD or an exchange maneuver. All aneurysms in which this technique was utilized were retrospectively reviewed. Results: Twenty-eight patients (20 females) with 30 treated aneurysms were identified. The mean aneurysm diameter was 10.2 ± 6.6 mm. Technical success rate was 96.6% (29/30 aneurysms). There was no mortality or permanent morbidity related to the procedures. Except for the patient treated for an iatrogenic, surgery-related internal carotid artery pseudoaneurysm who died secondary to consequences of multiple surgeries, no cases of mortality or permanent morbidity were noted. Complete aneurysm occlusion rates were 78.2%, 82.1%, and 95.2% at 0–3, 3–6, and 9–12 months, respectively. None of the patients were re-treated. Conclusion: EFT is a simple and fast technique which was not associated with adverse effects in our series. The higher aneurysm obliteration rate obtained with EFT is probably the result of better wall apposition of the SFD.
Sprache
Englisch
Identifikatoren
ISSN: 1793-5482
eISSN: 2248-9614
DOI: 10.4103/ajns.AJNS_374_19
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7591168

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX