Results of First In Vivo Trial of an Acoustic Self-Tonometer
Ist Teil von
  • Translational vision science & technology, 2020-08, Vol.9 (9), p.18-18
Ort / Verlag
United States: The Association for Research in Vision and Ophthalmology
Erscheinungsjahr
2020
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • Glaucoma is the world's most common cause of irreversible blindness, which makes early diagnosis, with the goal of preserving vision, essential. The current medical intervention is to reduce intraocular pressure (IOP) to slow down progression of the disease. The main goal of this study was to test a novel handheld acoustic self-tonometer on humans. A sound pressure pulse generated by a loudspeaker causes the eye to vibrate. A pressure chamber is placed on the human orbit to form a coupled system comprised of the patient's eye, the enclosed air, and the loudspeaker. A displacement sensor in front of the loudspeaker membrane allows the dynamic behavior of the entire system to be detected. For this clinical trial series, a prototype of the acoustic self-tonometer principle was applied. The resulting membrane oscillation data showed sensitivity of patient IOP, but direct allocation of the measured damping and frequency to the IOP was not significant. For this reason, an artificial neural network was used to find relationships among the subjects' biometric eye parameters in combination with the self-tonometer data for the IOP reference. An expanded measurement uncertainty ( = 2) equal to 6.53 mm Hg was determined for the self-tonometer in a Bland-Altman analysis using Goldmann applanation tonometer reference measurements. The usability and success rate of producing valid measurement values with the device during self-measurements by test subjects was nearly 92%. The cross-sensitivities observed require compensation in a possible redesign phase to reduce the measurement uncertainty by at least 25% to the maximum of 5 mm Hg required to seek medical device approval. Building on successful laboratory experiments with pig eyes, this article reports the results of testing the acoustic tonometer on humans.
Sprache
Englisch
Identifikatoren
ISSN: 2164-2591
eISSN: 2164-2591
DOI: 10.1167/tvst.9.9.18
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7442865

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX