Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 3 von 1126

Details

Autor(en) / Beteiligte
Titel
Do Fluid-Attenuated Inversion Recovery Vascular Hyperintensities Represent Good Collaterals before Reperfusion Therapy?
Ist Teil von
  • American journal of neuroradiology : AJNR, 2018-01, Vol.39 (1), p.77-83
Ort / Verlag
United States: American Society of Neuroradiology
Erscheinungsjahr
2018
Quelle
EZB Free E-Journals
Beschreibungen/Notizen
  • In acute ischemic stroke, whether FLAIR vascular hyperintensities represent good or poor collaterals remains controversial. We hypothesized that extensive FLAIR vascular hyperintensities correspond to good collaterals, as indirectly assessed by the hypoperfusion intensity ratio. We included 244 consecutive patients eligible for reperfusion therapy with MCA stroke and pretreatment MR imaging with both FLAIR and PWI. The FLAIR vascular hyperintensity score was based on ASPECTS, ranging from 0 (no FLAIR vascular hyperintensity) to 7 (FLAIR vascular hyperintensities abutting all ASPECTS cortical areas). The hypoperfusion intensity ratio was defined as the ratio of the time-to-maximum >10-second over time-to-maximum >6-second lesion volumes. The median hypoperfusion intensity ratio was used to dichotomize good (low hypoperfusion intensity ratio) versus poor (high hypoperfusion intensity ratio) collaterals. We then studied the association between FLAIR vascular hyperintensity extent and hypoperfusion intensity ratio. Hypoperfusion was present in all patients, with a median hypoperfusion intensity ratio of 0.35 (interquartile range, 0.19-0.48). The median FLAIR vascular hyperintensity score was 4 (interquartile range, 3-5). The FLAIR vascular hyperintensities were more extensive in patients with good collaterals (hypoperfusion intensity ratio ≤0.35) than with poor collaterals (hypoperfusion intensity ratio >0.35; = .016). The FLAIR vascular hyperintensity score was independently associated with good collaterals ( = .002). In patients eligible for reperfusion therapy, FLAIR vascular hyperintensity extent was associated with good collaterals, as assessed by the pretreatment hypoperfusion intensity ratio. The ASPECTS assessment of FLAIR vascular hyperintensities could be used to rapidly identify patients more likely to benefit from reperfusion therapy.
Sprache
Englisch
Identifikatoren
ISSN: 0195-6108
eISSN: 1936-959X
DOI: 10.3174/ajnr.a5431
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7410693

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX