Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 5 von 197

Details

Autor(en) / Beteiligte
Titel
Comparison of in-hospital outcomes and readmissions for valve-in-valve transcatheter aortic valve replacement vs. reoperative surgical aortic valve replacement: a contemporary assessment of real-world outcomes
Ist Teil von
  • European heart journal, 2020-08, Vol.41 (29), p.2747-2755
Ort / Verlag
England: Oxford University Press
Erscheinungsjahr
2020
Quelle
Oxford Journals 2020 Medicine
Beschreibungen/Notizen
  • Abstract Aims We sought to perform a head-to-head comparison of contemporary 30-day outcomes and readmissions between valve-in-valve transcatheter aortic valve replacement (VIV-TAVR) patients and a matched cohort of high-risk reoperative surgical aortic valve replacement (re-SAVR) patients using a large, multicentre, national database. Methods and results We utilized the nationally weighted 2012–16 National Readmission Database claims to identify all US adult patients with degenerated bioprosthetic aortic valves who underwent either VIV-TAVR (n = 3443) or isolated re-SAVR (n = 3372). Thirty-day outcomes were compared using multivariate analysis and propensity score matching (1:1). Unadjusted, VIV-TAVR patients had significantly lower 30-day mortality (2.7% vs. 5.0%), 30-day morbidity (66.4% vs. 79%), and rates of major bleeding (35.8% vs. 50%). On multivariable analysis, re-SAVR was a significant risk factor for both 30-day mortality [adjusted odds ratio (aOR) of VIV-SAVR (vs. re-SAVR) 0.48, 95% confidence interval (CI) 0.28–0.81] and 30-day morbidity [aOR for VIV-TAVR (vs. re-SAVR) 0.54, 95% CI 0.43–0.68]. After matching (n = 2181 matched pairs), VIV-TAVR was associated with lower odds of 30-day mortality (OR 0.41, 95% CI 0.23–0.74), 30-day morbidity (OR 0.53, 95% CI 0.43–0.72), and major bleeding (OR 0.66, 95% CI 0.51–0.85). Valve-in-valve TAVR was also associated with shorter length of stay (median savings of 2 days, 95% CI 1.3–2.7) and higher odds of routine home discharges (OR 2.11, 95% CI 1.61–2.78) compared to re-SAVR. Conclusion In this large, nationwide study of matched high-risk patients with degenerated bioprosthetic aortic valves, VIV-TAVR appears to confer an advantage over re-SAVR in terms of 30-day mortality, morbidity, and bleeding complications. Further studies are warranted to benchmark in low- and intermediate-risk patients and to adequately assess longer-term efficacy.
Sprache
Englisch
Identifikatoren
ISSN: 0195-668X
eISSN: 1522-9645
DOI: 10.1093/eurheartj/ehaa252
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7395321

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX