Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 14 von 9214

Details

Autor(en) / Beteiligte
Titel
Serum and Plasma Neutrophil Gelatinase Associated Lipocalin (NGAL) Levels are Not Equivalent in Patients Admitted to Intensive Care
Ist Teil von
  • Journal of clinical laboratory analysis, 2014-03, Vol.28 (2), p.163-167
Ort / Verlag
United States: Blackwell Publishing Ltd
Erscheinungsjahr
2014
Quelle
Wiley-Blackwell Journals
Beschreibungen/Notizen
  • Background Neutrophil gelatinase associated lipocalin (NGAL) is proposed as a biomarker of acute kidney injury (AKI). NGAL has been studied in a range of body fluids including serum and EDTA plasma. The aim of the present study was to establish relationship between serum NGAL concentrations and EDTA plasma NGAL concentrations in patients admitted to intensive care units (ICUs) and whether these determinations are directly comparable in this setting. Methods NGAL was measured in 40 paired samples of serum and EDTA plasma from 25 patients admitted to intensive care with a commercial particle‐enhanced turbidimetric immunoassay (The NGAL Test™, BioPorto Diagnostics A/S, Gentofte, Denmark) on a Roche Hitachi 917 (Roche‐Hitachi, Inc., Tokyo, Japan) analyzer. Results Serum NGAL concentrations ranged from 26.8 to 1,808 ng/ml (median 281 ng/ml, interquartile range (IQR) 453 ng/ml). EDTA plasma NGAL concentrations ranged from 25.7 to 1,752 ng/ml (median 225 ng/ml, IQR 352 ng/ml). The difference in NGAL concentrations in paired serum and EDTA plasma samples (serum– plasma) ranged from −13.8 to 321 ng/ml (median 79 ng/ml, IQR 116 ng/ml; difference from zero, P < 0.0001, Wilcoxon's signed rank test). Although serum and EDTA plasma values were correlated (Spearman's r = 0.95, P < 0.0001), Deming regression analysis showed a slope of 1.1 that was not significantly different from unity (95% confidence interval (CI) 1.0–1.1) and a highly significant intercept of 67.9 ng/ml with a wide confidence interval (95% CI 29.8–106). Conclusion NGAL concentration values measured in serum and EDTA plasma cannot be directly compared and should not be used as equivalents in studies of patients admitted to intensive care.
Sprache
Englisch
Identifikatoren
ISSN: 0887-8013
eISSN: 1098-2825
DOI: 10.1002/jcla.21662
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6807606

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX