Dual-Energy CT-Derived Iodine Content and Spectral Attenuation Analysis of Metastatic Versus Nonmetastatic Lymph Nodes in Squamous Cell Carcinoma of the Oropharynx
Ist Teil von
  • Tomography (Ann Arbor), 2018-06, Vol.4 (2), p.66-71
Ort / Verlag
United States: Grapho Publications, LLC
Erscheinungsjahr
2018
Link zum Volltext
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • The presence of a single nodal metastasis has significant prognostic and treatment implications for patients with head and neck cancer. This study aims to investigate whether dual-energy computed tomography (DECT)-derived iodine content and spectral attenuation curve analysis can improve detection of nodal metastasis in oropharyngeal carcinoma. Eight patients with newly diagnosed oropharyngeal squamous cell carcinoma and pathologically proven nodal metastatic disease (n = 13 metastatic nodes; n = 16 nonmetastatic nodes) who underwent contrast-enhanced DECT of the neck were retrospectively evaluated. DECT-derived iodine content (mg/mL) and monoenergetic attenuation values at 40 keV and 100 keV were obtained via circular regions of interest within metastatic and nonmetastatic cervical lymph nodes. Iodine content was significantly lower in metastatic nodes (0.96 ± 0.28 mg/mL) than in nonmetastatic nodes (1.65 ± 0.38 mg/mL; = .002). Iodine spectral attenuation slope was significantly lower in metastatic nodes (1.33 ± 0.49 mg/mL) than in nonmetastatic nodes (1.91 ± 0.64 mg/mL; = .015). A nodal iodine threshold of ≤1.3 mg/mL showed a sensitivity of 84.6% and a specificity of 75.0%, with an area under the curve of 0.839, < .0001. At a threshold value of ≤1.95 for nodal spectral attenuation slope, an optimized specificity of 92.3% and specificity of 50.0% was achieved, with an area under the curve of 0.68 ( = .049). DECT-derived quantitative iodine data and spectral attenuation curves may improve the diagnostic accuracy of computed tomography for nodal metastasis in patients with squamous cell carcinoma of the oropharynx.
Sprache
Englisch
Identifikatoren
ISSN: 2379-139X, 2379-1381
eISSN: 2379-139X
DOI: 10.18383/j.tom.2018.00009
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6127352
Format

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX