Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 4 von 303

Details

Autor(en) / Beteiligte
Titel
Validation of Aura Microwave Limb Sounder stratospheric water vapor measurements by the NOAA frost point hygrometer
Ist Teil von
  • Journal of geophysical research. Atmospheres, 2014-02, Vol.119 (3), p.1612-1625
Ort / Verlag
United States: Blackwell Publishing Ltd
Erscheinungsjahr
2014
Quelle
Wiley Online Library
Beschreibungen/Notizen
  • Differences between stratospheric water vapor measurements by NOAA frost point hygrometers (FPHs) and the Aura Microwave Limb Sounder (MLS) are evaluated for the period August 2004 through December 2012 at Boulder, Colorado, Hilo, Hawaii, and Lauder, New Zealand. Two groups of MLS profiles coincident with the FPH soundings at each site are identified using unique sets of spatiotemporal criteria. Before evaluating the differences between coincident FPH and MLS profiles, each FPH profile is convolved with the MLS averaging kernels for eight pressure levels from 100 to 26 hPa (~16 to 25 km) to reduce its vertical resolution to that of the MLS water vapor retrievals. The mean FPH − MLS differences at every pressure level (100 to 26 hPa) are well within the combined measurement uncertainties of the two instruments. However, the mean differences at 100 and 83 hPa are statistically significant and negative, ranging from −0.46 ± 0.22 ppmv (−10.3 ± 4.8%) to −0.10 ± 0.05 ppmv (−2.2 ± 1.2%). Mean differences at the six pressure levels from 68 to 26 hPa are on average 0.8% (0.04 ppmv), and only a few are statistically significant. The FPH − MLS differences at each site are examined for temporal trends using weighted linear regression analyses. The vast majority of trends determined here are not statistically significant, and most are smaller than the minimum trends detectable in this analysis. Except at 100 and 83 hPa, the average agreement between MLS retrievals and FPH measurements of stratospheric water vapor is better than 1%. Key Points No statistical biases between FPH and MLS H2O measurements: 68 to 26 hPa Significant biases between FPH and MLS H2O measurements at 83 and 100 hPa No significant temporal changes in FPH‐MLS measurement differences 2004‐2012
Sprache
Englisch
Identifikatoren
ISSN: 2169-897X
eISSN: 2169-8996
DOI: 10.1002/2013JD020757
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5571760

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX