Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 20 von 1983

Details

Autor(en) / Beteiligte
Titel
Diffusible iodine‐based contrast‐enhanced computed tomography (diceCT): an emerging tool for rapid, high‐resolution, 3‐D imaging of metazoan soft tissues
Ist Teil von
  • Journal of anatomy, 2016-06, Vol.228 (6), p.889-909
Ort / Verlag
England: Wiley Subscription Services, Inc
Erscheinungsjahr
2016
Quelle
Wiley-Blackwell Journals
Beschreibungen/Notizen
  • Morphologists have historically had to rely on destructive procedures to visualize the three‐dimensional (3‐D) anatomy of animals. More recently, however, non‐destructive techniques have come to the forefront. These include X‐ray computed tomography (CT), which has been used most commonly to examine the mineralized, hard‐tissue anatomy of living and fossil metazoans. One relatively new and potentially transformative aspect of current CT‐based research is the use of chemical agents to render visible, and differentiate between, soft‐tissue structures in X‐ray images. Specifically, iodine has emerged as one of the most widely used of these contrast agents among animal morphologists due to its ease of handling, cost effectiveness, and differential affinities for major types of soft tissues. The rapid adoption of iodine‐based contrast agents has resulted in a proliferation of distinct specimen preparations and scanning parameter choices, as well as an increasing variety of imaging hardware and software preferences. Here we provide a critical review of the recent contributions to iodine‐based, contrast‐enhanced CT research to enable researchers just beginning to employ contrast enhancement to make sense of this complex new landscape of methodologies. We provide a detailed summary of recent case studies, assess factors that govern success at each step of the specimen storage, preparation, and imaging processes, and make recommendations for standardizing both techniques and reporting practices. Finally, we discuss potential cutting‐edge applications of diffusible iodine‐based contrast‐enhanced computed tomography (diceCT) and the issues that must still be overcome to facilitate the broader adoption of diceCT going forward.
Sprache
Englisch
Identifikatoren
ISSN: 0021-8782
eISSN: 1469-7580
DOI: 10.1111/joa.12449
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5341577

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX