UNIVERSI
TÄ
TS-
BIBLIOTHEK
P
ADERBORN
Anmelden
Menü
Menü
Start
Hilfe
Blog
Weitere Dienste
Neuerwerbungslisten
Fachsystematik Bücher
Erwerbungsvorschlag
Bestellung aus dem Magazin
Fernleihe
Einstellungen
Sprache
Deutsch
Deutsch
Englisch
Farbschema
Hell
Dunkel
Automatisch
Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist
gegebenenfalls
nur via VPN oder Shibboleth (DFN-AAI) möglich.
mehr Informationen...
Universitätsbibliothek
Katalog
Suche
Details
Zur Ergebnisliste
Ergebnis 7 von 43
Datensatz exportieren als...
BibTeX
Sparse‐SEMAC: rapid and improved SEMAC metal implant imaging using SPARSE‐SENSE acceleration
Magnetic resonance in medicine, 2017-07, Vol.78 (1), p.79-87
Otazo, Ricardo
Nittka, Mathias
Bruno, Mary
Raithel, Esther
Geppert, Christian
Gyftopoulos, Soterios
Recht, Michael
Rybak, Leon
2017
Volltextzugriff (PDF)
Details
Autor(en) / Beteiligte
Otazo, Ricardo
Nittka, Mathias
Bruno, Mary
Raithel, Esther
Geppert, Christian
Gyftopoulos, Soterios
Recht, Michael
Rybak, Leon
Titel
Sparse‐SEMAC: rapid and improved SEMAC metal implant imaging using SPARSE‐SENSE acceleration
Ist Teil von
Magnetic resonance in medicine, 2017-07, Vol.78 (1), p.79-87
Ort / Verlag
United States: Wiley Subscription Services, Inc
Erscheinungsjahr
2017
Quelle
Wiley Online Library Journals Frontfile Complete
Beschreibungen/Notizen
Purpose To develop an accelerated SEMAC metal implant MRI technique (Sparse‐SEMAC) with reduced scan time and improved metal distortion correction. Methods Sparse‐SEMAC jointly exploits the inherent sparsity along the additional phase‐encoding dimension and multicoil encoding capabilities to significantly accelerate data acquisition. A prototype pulse sequence with pseudorandom ky‐kz undersampling and an inline image reconstruction was developed for integration in clinical studies. Three patients with hip implants were imaged using the proposed Sparse‐SEMAC with eight‐fold acceleration and compared with the standard‐SEMAC technique used in clinical studies (three‐fold GRAPPA acceleration). Measurements were performed with SEMAC‐encoding steps (SES) = 15 for Sparse‐SEMAC and SES = 9 for Standard‐SEMAC using high spatial resolution Proton Density (PD) and lower‐resolution STIR acquisitions. Two expert musculoskeletal (MSK) radiologists performed a consensus reading to score image‐quality parameters. Results Sparse‐SEMAC enables up to eight‐fold acceleration of data acquisition that results in two‐fold scan time reductions, compared with Standard‐SEMAC, with improved metal artifact correction for patients with hip implants without degrading spatial resolution. Conclusion The high acceleration enabled by Sparse‐SEMAC would enable clinically feasible examination times with improved correction of metal distortion. Magn Reson Med 78:79–87, 2017. © 2016 International Society for Magnetic Resonance in Medicine
Sprache
Englisch
Identifikatoren
ISSN: 0740-3194
eISSN: 1522-2594
DOI: 10.1002/mrm.26342
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5266741
Format
–
Schlagworte
Bone implants
,
Coding
,
Control systems
,
Data acquisition
,
Distortion
,
High acceleration
,
Hip
,
Image processing
,
Image quality
,
Image reconstruction
,
iterative reconstruction
,
Magnetic resonance imaging
,
metal artifacts
,
metallic implants
,
Metals
,
parallel imaging
,
Patients
,
Proton density (concentration)
,
Pseudorandom sequences
,
SPARSE‐SENSE
,
Spatial discrimination
,
Spatial resolution
,
Transplants & implants
Weiterführende Literatur
Empfehlungen zum selben Thema automatisch vorgeschlagen von
bX