UNIVERSI
TÄ
TS-
BIBLIOTHEK
P
ADERBORN
Anmelden
Menü
Menü
Start
Hilfe
Blog
Weitere Dienste
Neuerwerbungslisten
Fachsystematik Bücher
Erwerbungsvorschlag
Bestellung aus dem Magazin
Fernleihe
Einstellungen
Sprache
Deutsch
Deutsch
Englisch
Farbschema
Hell
Dunkel
Automatisch
Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist
gegebenenfalls
nur via VPN oder Shibboleth (DFN-AAI) möglich.
mehr Informationen...
Universitätsbibliothek
Katalog
Suche
Details
Zur Ergebnisliste
Ergebnis 22 von 202
Datensatz exportieren als...
BibTeX
Q-space truncation and sampling in diffusion spectrum imaging
Magnetic resonance in medicine, 2016-12, Vol.76 (6), p.1750-1763
Tian, Qiyuan
Rokem, Ariel
Folkerth, Rebecca D.
Nummenmaa, Aapo
Fan, Qiuyun
Edlow, Brian L.
McNab, Jennifer A.
2016
Volltextzugriff (PDF)
Details
Autor(en) / Beteiligte
Tian, Qiyuan
Rokem, Ariel
Folkerth, Rebecca D.
Nummenmaa, Aapo
Fan, Qiuyun
Edlow, Brian L.
McNab, Jennifer A.
Titel
Q-space truncation and sampling in diffusion spectrum imaging
Ist Teil von
Magnetic resonance in medicine, 2016-12, Vol.76 (6), p.1750-1763
Ort / Verlag
United States: Blackwell Publishing Ltd
Erscheinungsjahr
2016
Quelle
Wiley Online Library
Beschreibungen/Notizen
Purpose To characterize the q‐space truncation and sampling on the spin‐displacement probability density function (PDF) in diffusion spectrum imaging (DSI). Methods DSI data were acquired using the MGH‐USC connectome scanner (Gmax = 300 mT/m) with bmax = 30,000 s/mm2, 17 × 17 × 17, 15 × 15 × 15 and 11 × 11 × 11 grids in ex vivo human brains and bmax = 10,000 s/mm2, 11 × 11 × 11 grid in vivo. An additional in vivo scan using bmax=7,000 s/mm2, 11 × 11 × 11 grid was performed with a derated gradient strength of 40 mT/m. PDFs and orientation distribution functions (ODFs) were reconstructed with different q‐space filtering and PDF integration lengths, and from down‐sampled data by factors of two and three. Results Both ex vivo and in vivo data showed Gibbs ringing in PDFs, which becomes the main source of artifact in the subsequently reconstructed ODFs. For down‐sampled data, PDFs interfere with the first replicas or their ringing, leading to obscured orientations in ODFs. Conclusion The minimum required q‐space sampling density corresponds to a field‐of‐view approximately equal to twice the mean displacement distance (MDD) of the tissue. The 11 × 11 × 11 grid is suitable for both ex vivo and in vivo DSI experiments. To minimize the effects of Gibbs ringing, ODFs should be reconstructed from unfiltered q‐space data with the integration length over the PDF constrained to around the MDD. Magn Reson Med 76:1750–1763, 2016. © 2016 International Society for Magnetic Resonance in Medicine
Sprache
Englisch
Identifikatoren
ISSN: 0740-3194
eISSN: 1522-2594
DOI: 10.1002/mrm.26071
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4942411
Format
–
Schlagworte
aliasing artifacts
,
diffusion spectrum imaging
,
ex vivo imaging
,
Gibbs ringing artifacts
,
high b-value
,
q-space truncation and sampling
Weiterführende Literatur
Empfehlungen zum selben Thema automatisch vorgeschlagen von
bX