Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 13 von 522

Details

Autor(en) / Beteiligte
Titel
A rapid field test for the measurement of bovine serum immunoglobulin G using attenuated total reflectance infrared spectroscopy
Ist Teil von
  • BMC veterinary research, 2015-08, Vol.11 (1), p.218-218, Article 218
Ort / Verlag
England: BioMed Central Ltd
Erscheinungsjahr
2015
Quelle
EZB-FREE-00999 freely available EZB journals
Beschreibungen/Notizen
  • Following the recent development of a new approach to quantitative analysis of IgG concentrations in bovine serum using transmission infrared spectroscopy, the potential to measure IgG levels using technology and a device better designed for field use was investigated. A method using attenuated total reflectance infrared (ATR) spectroscopy in combination with partial least squares (PLS) regression was developed to measure bovine serum IgG concentrations. ATR spectroscopy has a distinct ease-of-use advantage that may open the door to routine point-of-care testing. Serum samples were collected from calves and adult cows, tested by a reference RID method, and ATR spectra acquired. The spectra were linked to the RID-IgG concentrations and then randomly split into two sets: calibration and prediction. The calibration set was used to build a calibration model, while the prediction set was used to assess the predictive performance and accuracy of the final model. The procedure was repeated for various spectral data preprocessing approaches. For the prediction set, the Pearson's and concordance correlation coefficients between the IgG measured by RID and predicted by ATR spectroscopy were both 0.93. The Bland Altman plot revealed no obvious systematic bias between the two methods. ATR spectroscopy showed a sensitivity for detection of failure of transfer of passive immunity (FTPI) of 88 %, specificity of 100 % and accuracy of 94 % (with IgG <1000 mg/dL as the FTPI cut-off value). ATR spectroscopy in combination with multivariate data analysis shows potential as an alternative approach for rapid quantification of IgG concentrations in bovine serum and the diagnosis of FTPI in calves.
Sprache
Englisch
Identifikatoren
ISSN: 1746-6148
eISSN: 1746-6148
DOI: 10.1186/s12917-015-0539-x
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4546031

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX