Multiplexed analysis of steroid hormones in human serum using novel microflow tile technology and LC–MS/MS
Ist Teil von
  • Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 2013-09, Vol.934, p.16-21
Ort / Verlag
Netherlands: Elsevier B.V
Erscheinungsjahr
2013
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • •Microflow technology reduces solvent consumption 150 fold.•Microflow technology allows for improved peak separation.•Microflow technology reduces sample consumption up to 800 fold.•Microflow technology allows for a 100–400 fold increase in on-column sensitivity.•Interfering isomeric matrix compounds can be distinguished by LC–MS/MS but not immunoassay. A novel microfluidic chromatography device coupled with tandem mass spectrometry (LC–MS/MS) was utilized for the multiplex analysis of 5 steroids (testosterone, dihydrotestosterone, progesterone, cortisol, cortisone) in human serum. The use of microfluidics allowed for reduction of the chromatographic flow rate to 3μl/min with overall method run times comparable to standard flow LC–MS/MS methods reported in the literature, corresponding to a 150 fold decrease in solvent consumption. Furthermore, a simple sample preparation protocol was employed requiring injection of only 0.5μl of sample, corresponding to a 100–400 fold increase in on-column sensitivity as compared to published standard flow assays. The measured LOQ for both testosterone and progesterone was 0.4ng/mL, representing an improvement over reported literature values obtained by standard flow methods employing comparable sample preparation and large injection volumes. The LOQs for cortisol (1.9ng/mL), cortisone (0.3ng/mL), and dihydrotestosterone (1.4ng/mL) were all within a biologically relevant range. A comparison of clinical serum samples was performed for the analysis of testosterone using this microfluidic LC–MS/MS assay and the Beckman Access II automated antibody-based measurement system. The immunoassay results were systematically higher due to matrix interference which was easily resolved with the increased chromatographic resolution obtained in the microflow LC–MS/MS assay.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX