Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 7 von 55

Details

Autor(en) / Beteiligte
Titel
An in vivo kinematic comparison of dynamic lumbar stabilization to lumbar discectomy and posterior lumbar fusion using radiostereometric analysis
Ist Teil von
  • International journal of spine surgery, 2012-12, Vol.6 (1), p.87-92
Ort / Verlag
Netherlands: Elsevier Inc
Erscheinungsjahr
2012
Link zum Volltext
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Abstract Background Biomechanical studies have shown that dynamic stabilization restores the neutral zone and stabilizes the motion segment. Unfortunately, there are limitations to clinical measurement of lumbar motion segments when using routine radiographs. Radiostereometric analysis is a 3-dimensional technique and can measure the spinal motion segment more accurately than techniques using plain film radiographs. The purpose of this study was measure and compare the range of motion after dynamic stabilization, posterior lumbar fusion (PLF), and lumbar discectomy. Methods Four patients who underwent lumbar decompression and dynamic stabilization (Dynesys; Zimmer Spine, Inc., Warsaw, Indiana) for treatment of lumbar spondylosis were compared with 4 patients with a similar diagnosis who were treated by PLF and pedicle screw fixation (PLF group) and 8 patients who had undergone lumbar microdiscectomy (discectomy group) for treatment of radiculopathy. During the surgical procedure, 3 to 5 tantalum beads were placed into each of the operative segments. The patients were followed up postoperatively at 1 month, 1 year, and 2 years. At each follow-up time point, segmental motions (flexion, extension, and total sagittal range of motion [SROM]) were measured by radiostereometric analysis. Results Flexion, extension, and SROM measured 1.0° ± 0.9°, 1.5° ± 1.3°, and 2.3° ± 1.2°, respectively, in the Dynesys group; 1.0° ± 0.6°, 1.1° ± 0.9°, and 1.5° ± 0.6°, respectively, in the PLF group; and 2.9° ± 2.4°, 2.3° ± 1.5°, and 4.7° ± 2.2°, respectively, in the discectomy group. No significant difference in motion was seen between the Dynesys and PLF groups or between the Dynesys and discectomy groups in extension. Significant differences in motions were seen between the PLF and discectomy groups and between the Dynesys and discectomy groups in flexion ( P = .007) and SROM ( P = .002). There was no significant change in the measured motions over time. Conclusions In this study a significantly lower amount of motion was seen after dynamic stabilization and PLF when compared with discectomy. A future study with a larger cohort is necessary to examine what effect, if any, these motions have on clinical outcomes.
Sprache
Englisch
Identifikatoren
ISSN: 2211-4599
eISSN: 2211-4599
DOI: 10.1016/j.ijsp.2012.02.003
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4300887

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX