Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 20 von 524

Details

Autor(en) / Beteiligte
Titel
The relation of location-specific epicardial adipose tissue thickness and obstructive coronary artery disease: systemic review and meta-analysis of observational studies
Ist Teil von
  • BMC cardiovascular disorders, 2014-05, Vol.14 (1), p.62-62, Article 62
Ort / Verlag
England: BioMed Central Ltd
Erscheinungsjahr
2014
Link zum Volltext
Quelle
springer (창간호~2014)
Beschreibungen/Notizen
  • There is growing evidence about the importance of epicardial adiposity on cardiometabolic risk. However, the relation of location-specific epicardial adipose tissue (EAT) thickness to coronary atherosclerotic burden is still unclear. This meta-analysis was used to study the relations between location-specific EAT thickness and obstructive coronary artery disease (CAD). A systemic literature search to identify eligible studies that met the inclusion criteria from the beginning until January 2014 was made. We conducted the meta-analysis of all included 10 published studies. Pre-specified subgroup analyses were performed according to ethnicity, body mass index, diagnostic tools for CAD, and measurement tool if presence of high heterogeneity between studies. Potential publication bias was also assessed. We identified ten observed studies with a total of 1625 subjects for planned comparison. With regard to the association between obstructive CAD and location-specific EAT thickness at the right ventricular free wall, caution is warranted. The pooled estimate showed that location-specific EAT thickness at the right ventricular free wall was significantly higher in the CAD group than non-CAD group (standardized mean difference (SMD): 0.70 mm, 95% CI: 0.26-1.13, P = 0.002), although heterogeneity was high (I2 = 93%). It should be clear that only the result of echocardiography-based studies showed a significant association (SMD: 0.98 mm, 95% CI: 0.43-1.53, P = 0.0005), and the result of all included CT-based studies showed a non-significant association (SMD: 0.06 mm, 95% CI: -0.12-0.25, P = 0.50). In the subgroup analysis, the "diagnostic tools for CAD" or "measurement tool of EAT thickness" are potential major sources of heterogeneity between studies. With regard to location-specific EAT thickness at the left atrioventricular (AV) groove, it was significantly higher in the CAD group than non-CAD group (SMD: 0.74 mm, 95% CI: 0.55-0.92, P <0.00001; I2 = 0%). Our meta-analysis suggests that significantly elevated location-specific EAT thickness at the left AV groove is associated with obstructive CAD. Based on the current evidence, the location-specific EAT thickness at the left AV groove appears to be a good predictor in obstructive CAD, especially in Asian populations. Furthermore well-designed studies are warranted because of the current limited number of studies.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX