Detection of interfraction displacement and volume variance during radiotherapy of primary thoracic esophageal cancer based on repeated four-dimensional CT scans
Ist Teil von
  • Radiation oncology (London, England), 2013-09, Vol.8 (1), p.224-224, Article 224
Ort / Verlag
England: BioMed Central Ltd
Erscheinungsjahr
2013
Quelle
MEDLINE
Beschreibungen/Notizen
  • To investigate the interfraction displacement and volume variation of primary thoracic esophagus carcinoma with enhanced four-dimensional computed tomography (4DCT) scanning during fractionated radiotherapy. 4DCT data sets were acquired at the time of treatment simulation and every ten fraction for each of 32 patients throughout treatment. Scans were registered to baseline (simulation) 4DCT scans by using bony landmarks. The gross tumor volumes (GTVs) were delineated on each data set. Coordinates of the GTV centroids were acquired on each respiration phase. Distance between center of the GTV contour on the simulation scan and the centers on subsequent scans were used to assess interfraction displacement between fractions. Volumes were constructed using three approaches: The GTV delineated from the maximum intensity projection (MIP) was defined IGTVMIP, all 10 GTVs were combined to form IGTV10, GTVmean was the average of all 10 phases of each GTV. Interfraction displacement in left-right (LR), anterior-posterior (AP), superior-inferior (SI) directions and 3D vector were 0.13 ± 0.09 cm, 0.16 ± 0.12 cm, 0.34 ± 0.26 cm and 0.43 ± 0.24 cm, respectively between the tenth fraction and simulation 4DCT scan. 0.14 ± 0.09 cm, 0.19 ± 0.16 cm, 0.45 ± 0.43 cm and 0.56 ± 0.40 cm in LR, AP, SI and 3D vector respectively between the twentieth fraction and simulation 4DCT scan. Displacement in SI direction was larger than LR and AP directions during treatment. For distal esophageal cancer, increased interfraction displacements were observed in SI direction and 3D vector (P = 0.002 and P = 0.001, respectively) during radiotherapy. The volume of GTVmean, IGTVMIP, and IGTV10 decreased significantly at the twentieth fraction for middle (median: 34.01%, 33.09% and 28.71%, respectively) and distal (median: 22.76%, 25.27% and 23.96%, respectively) esophageal cancer, but for the upper third, no significant variation were observed during radiotherapy. Interfractional displacements in SI direction were larger than LR and AP directions. For distal location, significant changes were observed in SI direction and 3D vector during radiotherapy. For middle and distal locations, the best time to reset position should be selected at the twentieth fraction when the primary tumor target volume changed significantly, and it was preferable to guide target correction and planning modification.
Sprache
Englisch
Identifikatoren
ISSN: 1748-717X
eISSN: 1748-717X
DOI: 10.1186/1748-717X-8-224
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4016114

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX