On the Significance of Motion Degradation in High-resolution 3D μMRI of Trabecular Bone
Ist Teil von
  • Academic radiology, 2011-10, Vol.18 (10), p.1205-1216
Ort / Verlag
United States: Elsevier Inc
Erscheinungsjahr
2011
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • Rationale and Objectives Subtle subject movement during high-resolution three-dimensional micro–magnetic resonance imaging of trabecular bone (TB) causes blurring, thereby rendering the data unreliable for quantitative analysis. In this work, the effects of translational and rotational motion displacements were evaluated qualitatively and quantitatively. Materials and Methods In experiment 1, motion was induced by applying various simulated and previously observed in vivo trajectories as phase shifts to k-space or rotation angles to k-space segments of a virtually motion-free data set. In experiment 2, images that were visually free of motion artifacts from two groups of 10 healthy individuals, differing in age, were selected to probe the effects of motion on TB parameters. In both experiments, images were rated for motion severity, and the scores were compared to a focus criterion, the normalized gradient squared. Results Strong correlations were observed between the motion quality scores and the corresponding normalized gradient squared values ( R2 = 0.52–0.64, P < .01). The results from experiment 1 demonstrated consistently lower image quality and alterations in structural parameters of 9% to 45% with increased amplitude of displacements. In experiment 2, the significant differences in structural parameter group means of the motion-free images were lost upon motion degradation. Autofocusing, a postprocessing correction method, partially recovered the sharpness of the original motion-free images in 13 of 20 subjects. Conclusions Quantitative TB structural measures are highly sensitive to subtle motion-induced degradation, which adversely affects precision and statistical power. The results underscore the influence of subject movement in high-resolution three-dimensional micro–magnetic resonance imaging and its correction for TB structure analysis.
Sprache
Englisch
Identifikatoren
ISSN: 1076-6332
eISSN: 1878-4046
DOI: 10.1016/j.acra.2011.06.006
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3168960

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX