Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 17 von 88

Details

Autor(en) / Beteiligte
Titel
Validation of ICA-based myogenic artifact correction for scalp and source-localized EEG
Ist Teil von
  • NeuroImage (Orlando, Fla.), 2010-02, Vol.49 (3), p.2416-2432
Ort / Verlag
United States: Elsevier Inc
Erscheinungsjahr
2010
Quelle
MEDLINE
Beschreibungen/Notizen
  • Muscle electrical activity, or “electromyogenic” (EMG) artifact, poses a serious threat to the validity of electroencephalography (EEG) investigations in the frequency domain. EMG is sensitive to a variety of psychological processes and can mask genuine effects or masquerade as legitimate neurogenic effects across the scalp in frequencies at least as low as the alpha band (8–13 Hz). Although several techniques for correcting myogenic activity have been described, most are subjected to only limited validation attempts. Attempts to gauge the impact of EMG correction on intracerebral source models (source “localization” analyses) are rarer still. Accordingly, we assessed the sensitivity and specificity of one prominent correction tool, independent component analysis (ICA), on the scalp and in the source-space using high-resolution EEG. Data were collected from 17 participants while neurogenic and myogenic activity was independently varied. Several protocols for classifying and discarding components classified as myogenic and non-myogenic artifact (e.g., ocular) were systematically assessed, leading to the exclusion of one-third to as much as three-quarters of the variance in the EEG. Some, but not all, of these protocols showed adequate performance on the scalp. Indeed, performance was superior to previously validated regression-based techniques. Nevertheless, ICA-based EMG correction exhibited low validity in the intracerebral source-space, likely owing to incomplete separation of neurogenic from myogenic sources. Taken with prior work, this indicates that EMG artifact can substantially distort estimates of intracerebral spectral activity. Neither regression- nor ICA-based EMG correction techniques provide complete safeguards against such distortions. In light of these results, several practical suggestions and recommendations are made for intelligently using ICA to minimize EMG and other common artifacts.
Sprache
Englisch
Identifikatoren
ISSN: 1053-8119
eISSN: 1095-9572
DOI: 10.1016/j.neuroimage.2009.10.010
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_2818255

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX