Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 5 von 5185
Evidence-based complementary and alternative medicine, 2008-12, Vol.5 (4), p.443-450
2008
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Skin Impedance Measurements for Acupuncture Research: Development of a Continuous Recording System
Ist Teil von
  • Evidence-based complementary and alternative medicine, 2008-12, Vol.5 (4), p.443-450
Ort / Verlag
United States: Oxford University Press
Erscheinungsjahr
2008
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Skin impedance at acupuncture points (APs) has been used as a diagnostic/therapeutic aid for more than 50 years. Currently, researchers are evaluating the electrophysiologic properties of APs as a possible means of understanding acupuncture's mechanism. To comprehensively assess the diagnostic, therapeutic and mechanistic implications of acupuncture point skin impedance, a device capable of reliably recording impedances from 100 kΩ to 50 MΩ at multiple APs over extended time periods is needed. This article describes design considerations, development and testing of a single channel skin impedance system (hardware, control software and customized electrodes). The system was tested for accuracy against known resistors and capacitors. Two electrodes (the AMI and the ORI) were compared for reliability of recording over 30 min. Two APs (LU 9 and PC 6) and a nearby non-AP site were measured simultaneously in four individuals for 60 min. Our measurement system performed accurately (within 5%) against known resistors (580 kΩ-10 MΩ) and capacitors (10 nF-150 nF). Both the AMI electrode and the modified ORI electrode recorded skin impedance reliably on the volar surface of the forearm (r = 0.87 and r = 0.79, respectively). In four of four volunteers tested, skin impedance at LU 9 was less than at the nearby non-AP site. In three of four volunteers skin impedance was less at PC 6 than at the nearby non-AP site. We conclude that our system is a suitable device upon which we can develop a fully automated multi-channel device capable of recording skin impedance at multiple APs simultaneously over 24 h.
Sprache
Englisch
Identifikatoren
ISSN: 1741-427X
eISSN: 1741-4288
DOI: 10.1093/ecam/nem060
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_2586308
Format
Schlagworte
Original – Basic Science

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX