Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 14 von 481

Details

Autor(en) / Beteiligte
Titel
Ion Heating in Advanced Dielectric Barrier Discharge Ion Sources for Ambient Mass Spectrometry
Ist Teil von
  • Journal of the American Society for Mass Spectrometry, 2023-06, Vol.34 (6), p.1145-1152
Ort / Verlag
United States: American Chemical Society
Erscheinungsjahr
2023
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Dielectric barrier discharges (DBD) are highly versatile plasma sources for forming ions at atmospheric pressure and near ambient temperatures for the rapid, direct, and sensitive analysis of molecules by mass spectrometry (MS). Ambient ion sources should ideally form intact ions, as in-source fragmentation can limit sensitivity, increase spectral complexity, and hinder interpretation. Here, we report the measurement of ion internal energy distributions for the four primary classes of DBD-based ion sources, specifically DBD ionization (DBDI), low-temperature plasma (LTP), flexible microtube plasma (FμTP), and active capillary plasma ionization (ACaPI), in addition to atmospheric pressure chemical ionization (APCI) using para-substituted benzylammonium thermometer ions. Surprisingly, the average extent of energy deposited by the use of ACaPI (90.6 kJ mol–1) was ∼40 kJ mol–1 lower than the other ion sources (DBDI, LTP, FμTP, and APCI; 130.2 to 134.1 kJ mol–1) in their conventional configurations, and slightly higher than electrospray ionization (80.8 kJ mol–1). The internal energy distributions did not depend strongly on the sample introduction conditions (i.e., the use of different solvents and sample vaporization temperatures) or the DBD plasma conditions (i.e., maximum applied voltage). By positioning the DBDI, LTP, and FμTP plasma jets on axis with the capillary entrance to the mass spectrometer, the extent of internal energy deposition could be reduced by up to 20 kJ mol–1, although at the expense of sensitivity. Overall, the use of an active capillary-based DBD can result in substantially less fragmentation of ions with labile bonds than alternate DBD sources and APCI with comparably high sensitivity.
Sprache
Englisch
Identifikatoren
ISSN: 1044-0305
eISSN: 1879-1123
DOI: 10.1021/jasms.3c00087
Titel-ID: cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_10251516
Format

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX