Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
The Journal of the Acoustical Society of America, 1998-07, Vol.104 (1), p.442-452
1998
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Modulation detection interference in cochlear implant subjects
Ist Teil von
  • The Journal of the Acoustical Society of America, 1998-07, Vol.104 (1), p.442-452
Ort / Verlag
United States
Erscheinungsjahr
1998
Quelle
MEDLINE
Beschreibungen/Notizen
  • The aim of this study was to determine whether detection thresholds for amplitude modulated signals on a single electrode were influenced by a masking modulation on a second electrode in cochlear implant users. Data were collected from four post-linguistically deafened subjects using the Cochlear Limited prosthesis. Investigated were the effects of the spatial separation between test and masker electrodes, 0 to 5 electrodes (0 to 3.75 mm), and the amount of masking modulation: 24%, 48%, 72%, and 96% above detection thresholds. Initially, modulation detection thresholds for stimulation on a single electrode without masking modulation were obtained for a set of six electrodes in the middle of the array. Modulation detection thresholds on a fixed test electrode were then obtained with unmodulated and modulated masking on a second electrode, which was one of the six electrodes in the initial study. In both studies, thresholds were measured for modulated pulse duration at the modulation frequencies of 10-200 Hz. In the first study, the shape of the detection thresholds as a function of modulation frequency, the temporal modulation transfer function, generally resembled a low-pass filter for two subjects. For the other two subjects, the functions were relatively flat across modulation frequencies. In the second study, unmodulated masking resulted in a small elevation in detection thresholds across electrodes. Modulation detection interference (MDI), the difference between thresholds for the modulated maskers and the unmodulated masker, was greater for larger amounts of masking modulation than for smaller amounts of masking modulation. For three of the four subjects, MDI was higher for smaller spatial separations between the two electrodes than for larger spatial separations suggesting that a portion of MDI may be due to overlap of neural excitation distributions produced by stimulation on two electrodes in close proximity on the array.
Sprache
Englisch
Identifikatoren
ISSN: 0001-4966
eISSN: 1520-8524
DOI: 10.1121/1.423248
Titel-ID: cdi_pubmed_primary_9670536

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX