Heparin vs. saline for peripheral i.v. locks in children
Ist Teil von
Pediatric nursing, 1993-07, Vol.19 (4), p.405
Ort / Verlag
United States
Erscheinungsjahr
1993
Quelle
MEDLINE
Beschreibungen/Notizen
To determine the efficacy of saline versus heparin flush solution to maintain peripheral i.v. locks in a pediatric population.
A prospective, randomized, double-blind design was used. A sample of 124 peripheral i.vs. were flushed with either saline or heparin in saline. Subjects were infants over 28 days of age and children.
The heparin and saline groups were comparable for total hours duration of the i.v. and for incidence of complications.
Saline is efficacious in maintaining patency of peripheral i.v. locks in children over 28 days of age.