Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Videothermometry for assay of fescue foot in cattle
Ist Teil von
American journal of veterinary research, 1979-08, Vol.40 (8), p.1192
Ort / Verlag
United States
Erscheinungsjahr
1979
Quelle
MEDLINE
Beschreibungen/Notizen
Surface temperatures of hoofs of calves given toxic anion fractions of tall fescue were measured with an infrared sensitive camera. These changes expressed in terms of a weighted average coronary band temperature relate to clinical signs of fescue foot. The weighted average coronary band temperature values for control calves given saline solution were 27 to 31 C; those values of test calves given anion fractions of tall fescue were as low as 22 +/- 1 C. Videothermometry provides an independent, permanent, objective measure that is useful in assessing fescue-foot potential of tall fescue fractions by intraperitoneal injection. Videothermometry may also serve as a clinical means for determining progression of the total fescue foot syndrome.