Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...

Details

Autor(en) / Beteiligte
Titel
The Effects of Residual Femoral Deformity on Computed Contact Mechanics in Patients Treated With In Situ Fixation for Slipped Capital Femoral Epiphysis
Ist Teil von
  • Journal of pediatric orthopaedics, 2024-03, Vol.44 (3), p.e218-e225
Ort / Verlag
United States
Erscheinungsjahr
2024
Quelle
MEDLINE
Beschreibungen/Notizen
  • In situ fixation for treatment of slipped capital femoral epiphysis (SCFE) can stabilize the epiphysis and prevent further joint deformation but often leaves residual deformity that may adversely affect intra-articular contact mechanics. The purpose of this study was to investigate the relationship between residual deformity and contact mechanics in the post-SCFE hip. Patient-specific hip models were created for 19 patients with SCFE treated with in situ fixation. For each model, discrete element analysis was used to compute cumulative acetabular and femoral contact stress exposure during a walking gait cycle. Slip severity was evaluated for each patient using the two-dimensional Southwick angle and a novel three-dimensional (3D) assessment of multiplanar femoral deformity (3D slip angle). Of the SCFE cases, 2/7 mild (Southwick angle ≤30 degrees) had peak cumulative femoral exposures equivalent to that of severe (Southwick angle ≥60 degrees) cases. Severe SCFE cases had higher peak ( P = 0.015) and mean ( P = 0.028) femoral contact stress exposure and lower cumulative femoral contact area ( P = 0.003) than mild (Southwick angle ≤30 degrees) SCFE cases. Mean femoral contact stress exposure was also higher in severe SCFE cases than in moderate SCFE cases ( P = 0.027). Acetabular and femoral contact mechanics metrics typically demonstrated stronger correlations with 3D slip angle than two-dimensional Southwick angle. Increased slip severity adversely impacts intra-articular femoral contact mechanics. Contact mechanics metrics demonstrate higher correlations with 3D slip angle, indicating that this novel measurement may better describe global deformity and its relationship to intra-articular mechanics; however, the modest strength of these correlations may also imply that global impingement-generating deformity is not the primary factor driving contact mechanics in the post-SCFE hip. Greater slip severity adversely impacts contact mechanics in the post-SCFE hip. However, focal regions of high contact stress were seen even in mild SCFE deformities, suggesting some type of deformity correction should be considered even for mild slips to alleviate secondary impingement, address focal incongruities, and reduce osteoarthritis development/progression.
Sprache
Englisch
Identifikatoren
ISSN: 0271-6798
eISSN: 1539-2570
DOI: 10.1097/BPO.0000000000002596
Titel-ID: cdi_pubmed_primary_38108380

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX