Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 24 von 66
Journal of the American Academy of Orthopaedic Surgeons, 2023-01, Vol.31 (1), p.34
2023

Details

Autor(en) / Beteiligte
Titel
Outcomes After Abductor Reattachment to Proximal Femur Endoprosthesis After Tumor Resection
Ist Teil von
  • Journal of the American Academy of Orthopaedic Surgeons, 2023-01, Vol.31 (1), p.34
Ort / Verlag
United States
Erscheinungsjahr
2023
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • Resection of the proximal femur raises several challenges including restoration of the abductor mechanism. Few evaluated the outcomes of different techniques of abductor fixation to the proximal femur endoprosthesis. A retrospective review of patients who underwent proximal femoral arthroplasty with a minimum follow-up of 12 months was conducted. Patients were divided into two groups: (1) those with preserved greater trochanter (GT) reattached to the implant and (2) those with direct abductor muscle reattachment. Both groups were compared for surgical and functional outcomes. Group 1 patients were subdivided into those who received GT reinsertion using grip and cables and those reattached using sutures. Fifty-three patients were included with a mean follow-up of 49 months. There were 22 patients with reinserted GT and 31 patients with soft-tissue repair. The endoprosthesis revision rate was comparable between groups (P = 0.27); however, the incidence of dislocations was higher in group 2 (0/22 versus 6/31; P = 0.035). Trendelenburg gait (77% versus 74%), use of walking aids (68% versus 81%), and abductor muscle strength were comparable between both groups (P > 0.05). In group 1, 15 patients had GT reinsertion with grip and cables. Of those, five patients (33%) had cable rupture within 13 months of follow-up. GT displacement reached 12 mm at 12 months of follow-up in patients with grip and cables compared with 26 mm in patients with GT suture reinsertion (P < 0.05). Although GT preservation did not improve functional outcomes, it was associated with a lower dislocation rate despite frequent cable failure. Less displacement was observed when GT reattachment used grip and cables.
Sprache
Englisch
Identifikatoren
eISSN: 1940-5480
DOI: 10.5435/JAAOS-D-22-00369
Titel-ID: cdi_pubmed_primary_36548152

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX