Image-Free Fast Ultrasound for Measurement of Local Pulse Wave Velocity: In Vitro Validation and In Vivo Feasibility
Ist Teil von
  • IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2022-07, Vol.69 (7), p.2248-2256
Ort / Verlag
United States: IEEE
Erscheinungsjahr
2022
Quelle
IEEE Electronic Library Online
Beschreibungen/Notizen
  • Local pulse wave velocity (PWV), a metric of the target artery's stiffness, has been emerging in its clinical value and adoption. State-of-the-art ultrasound technologies used to evaluate local PWV based on pulse waves' features are sophisticated, non-real-time, and are not amenable for field and resource-constrained settings. In this work, we present an image-free ultrasound system to measure local PWV in real-time by employing a pair of ultrasound transducer elements. An in vitro study was performed on the arterial phantom to: 1) characterize the design aspects of the system and 2) validate its accuracy against beat-by-beat (invasive) local PWV measured by a reference dual-element catheter. Furthermore, a repeatability and reproducibility study on 33 subjects (21-52 years) investigated the in vivo measurement feasibility from the carotid artery. With the experimentally deduced optimal design (frame-rate <inline-formula> <tex-math notation="LaTeX">=500 </tex-math></inline-formula> Hz, RF sampling rate <inline-formula> <tex-math notation="LaTeX">=125 </tex-math></inline-formula> MHz, LPF cutoff <inline-formula> <tex-math notation="LaTeX">=14 </tex-math></inline-formula> Hz, and order <inline-formula> <tex-math notation="LaTeX">=4 </tex-math></inline-formula>), the system yielded repeatable beat-to-beat measurements (variability <inline-formula> <tex-math notation="LaTeX">=1.9 </tex-math></inline-formula>% and over 15 cycles) and achieved a high accuracy (root-mean-square-error <inline-formula> <tex-math notation="LaTeX">=0.19 </tex-math></inline-formula> m/s and absolute-percentage-error <inline-formula> <tex-math notation="LaTeX">=2.4 </tex-math></inline-formula>%) over a wide range of PWVs (2.7-11.4 m/s) from the phantom. Subsequently, on human subjects, the intra- and inter-operator PWV measurements were highly repeatable (intraclass correlation coefficient <inline-formula> <tex-math notation="LaTeX">>0.92 </tex-math></inline-formula>). The system does not impose a demand for special processors with high-computational power while offering real-time feedback on acquisition and measurement quality and provides local PWV online. Future large population and animal studies are required to establish the device's clinical usability.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX