Improved office blood pressure control by automatic delayed-reading oscillometric device
Ist Teil von
Hipertension y riesgo vascular, 2021-07, Vol.38 (3), p.119
Ort / Verlag
Spain
Erscheinungsjahr
2021
Quelle
MEDLINE
Beschreibungen/Notizen
Office blood pressure (BP) measurement is a recommended procedure, although the out-of-office BP measurements are increasingly used.
To know the degree of BP control by clinical measurement.
During November 2019 demographic and clinical data, office attended systolic BP (SBP) and diastolic BP (DBP) measured with an automatic device with delayed reading and, if performed, data from ambulatory BP monitoring (ABPM) were collected.
102 patients (67 men) were included, with a mean age of 64.9 years, 30% diabetic and 34% with cardiovascular complications. 70% had a controlled hypertesion (<140/90 mmHg) by office BP, the mean SBP was 131 ± 16.5 mmHg and the DBP was 73 ± 9.5 mmHg. Old age and diabetes were associated with uncontrolled hypertension. Thirty three patients had ABPM data, which allowed them to be classified according to the 24-hour BP into: 30% true normotension, 9% white-coat hypertension, 15% sustained hypertension, and 45% masked hypertension.
The use of automatic devices reduces the white-coat phenomenon, improving the % of patients with office BP controlled. However, this is not confirmed outside the clinic, showing the importance of ABPM in the evaluation of hypertension control. Office BP measurement is useful in patients initial assessment and also provides educational aspects, although the methodology must be optimized to define its clinical role.